Positioning (F)
To move the dehumidifier use the handle and run it on his wheels. The
dehumidifier must be simply placed in the room to be dehumidified
and started: the air inlet is in front, the air outlet is on the back.
It is advisable to place the dehumidifier in the coldest point of the
room, where normally the humidity level is higher, possibly near a
power socket.
Maintenance
The dehumidifiers of the TIGER and SUMO series need no particular
maintenance. It is advisable to dust them and keep the air intake and
outlet grids clean, check the air filter periodically and clean it if neces-
sary. Contact your dealer if it should function badly or breakdown. The
power supply cable has an M type connection; in the event of damages,
the cable must be replaced with a similar one only by experienced and
qualified staff.
!
ATTENTION: before doing anything on the ap-
pliance select the functioning mode 0, wait until
the unit stops then disconnect the power supply by
unplugging the machine.
Storage
The machines of the series TIGER and SUMO have been designed to
be easily stackable and this allows to considerably reduce the spaces
needed for storage.
• Keep the appliance in a room with a temperature between –25°C
and +55°C.
• When the appliance is still packed keep to the instructions on the
box.
• Do not place other heavy material on the box.
Before a long period of inactivity ...
• Disconnect the plug and empty the condensate collection tank (if
present);
• cover the machine to protect it from dust.
After a long period of inactivity ...
• The fan must turn freely without gripping;
• put the machine working following this manual's instructions.
Disposal of the product
Applicable in European Union countries only. The
crossed-out rubbish bin symbol indicates that the
product must be collected separately from other waste
at the end of its useful life. The user must therefore take
the appliance at the end of its useful life to a special
centre for electrical and electronic waste collection or
hand it back to the retailer on purchasing a new
product of an equivalent type, on a one-for-one basis.
Proper segregated waste collection of old appliances
for subsequent recycling, treatment and environmentally compatible
disposal helps avoid possible negative effects on the environment and
health and favours recycling of the materials the product is made of.
Improper disposal of the product by the user entails administrative
sanctions provided for in the legislation of individual countries.
14
All manuals and user guides at all-guides.com
WWiring diagram (B)
Common technical data
Technical data
ENGLISH
Ref. Description
Ref. Description
B1 Fan
B6 Control board
B2 Compressor
B7 Humidity probe
B3 Power board
B8 Cable, 10 poles
B4 Temperature probe
B5 Level switch
B10 Pump with tank
Tab.C – Wiring diagram
Working temperature [°C] +2 / +32
Working humidity [%U.R.] 40 / 95
Power supply 230 V, 50 Hz
Power absorption, stand-by [W] 1,2
Refrigerating gas charge [g] See label
Max pressure [kPa] 1500
Tab.D – Common data
Indicative handling volume [m³]
Condensate capacity [L/24hours]
Air flow [m³/hour]
Current absorption [A]
Power absorption [W]
Refrigerating gas
Noise level at 1 m distance [dBa]
Dry weight [Kg]
Water tank capacity [L]
(*) at 25°C and 65 %R.H. (**) at 30°C and 80% R.H.
Tab.E – Technical data
M1081-0_draft-0
B9 Solenoid valve
Tiger
Sumo
600
800
(*) 34,5
(*) 48
(**) 51
(**) 81
600
850
(*) 3,45
(*) 4,06
(**) 3,9
(**) 4,74
(*) 730
(*) 890
(**) 840
(**) 1050
R407c
R407c
61
64
38
59.7
6
-