Operating the appliance
This appliance only works when it is completely extended.
Note: Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Extending/retracting the appliance
:
Risk of injury!
Risk of jamming when retracting and extending the appliance.
Never reach into the moving area of the appliance while it is
being retracted or extended. Keep children at a safe distance.
:
Risk of injury!
Cookware set down within the movement area of the appliance
can fall over. Hot liquids that pour out can cause injury. Do not
set down any cookware within the movement area of the
appliance.
Extending the appliance
1.
Remove any objects from the area of movement of the
appliance.
#
Press the
button.
2.
The appliance extends fully. The fan starts at setting 2.
Retracting the appliance
Note: The filter cover must be closed completely.
Remove any objects from the area of movement of the
1.
appliance.
#
2.
Press and hold the
button for two seconds.
The appliance retracts fully. The light and fan are
automatically switched off.
Setting the fan
Note: Always adjust the fan strength to meet current conditions.
If there is a large build-up of steam or fumes, select a high fan
setting.
Switching on
#
Press the
button.
The fan starts at setting 2.
Press the + or - button to change the fan strength.
Switching off
#
Press the
button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
Press the
button while ventilation is switched on.
The intensive setting is activated.
After 10 minutes, the electronics automatically turn the
appliance down to the previously set ventilation setting. If you
wish to end the intensive setting before this time expires, press
the
button.
14
All manuals and user guides at all-guides.com
Fan run-on time
x
Press the
button.
The fan continues to operate for a further 15 minutes at level 1,
and then switches off automatically after this time. The
remaining run-on time is displayed in minutes on the display
panel.
If the lighting is switched on, this is also switched off after this
time.
x
Press the
button to end the fan run-on time early.
Lighting
The lighting can be switched on and off independently of the
ventilation.
@
Press the
button.
Setting the brightness
@
Press and hold the
button for 2 seconds.
The brightness is reduced.
@
Press the
button to reset to the maximum brightness.
Saturation display
When the metal grease filter or activated charcoal filter is
saturated, the corresponding symbol flashes:
ª
Metal grease filter:
'
Activated charcoal filter:
When this happens, do not delay cleaning the metal grease
filter or replacing the activated charcoal filter any further.
For instructions on how to clean the metal grease filter, please
refer to the section "Cleaning and maintenance".
Restoring the saturation displays
Switch off the motor.
Press and hold the "-" button for two seconds.
Switching over the display for circulating-air mode
For circulating-air mode, the electronic control display must be
switched over accordingly:
The extractor hood must be connected and switched off.
Press and hold the "+" button for 2 seconds until
twice on the display.
Repeatedly press the button to switch the electronic control
back to exhaust-air mode (
'
flashes
'
flashes once).