EtherWAN EX71 Serie Guide D'installation

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Unpacking
Open the carton and unpack the items. Your package should include:
One EX71000 hardened managed switch
One console cable
If any items are missing or damaged, notify your EtherWAN representative. If
possible, save the carton and packing material in case you need to ship or store the
switch in the future.
What Else You Need
Category 5 or better cable for RJ-45 ports
Appropriate fiber cables for fiber ports
Appropriate SFP cable for SFP ports
Personal computer with a DB-9 straight cable
Select a Location
Indoor use only, DIN Rail, wall-mount, rack, or cabinet.
Installation altitude should be less than 2000 meters.
Identify a power source within 6 feet (1.8 meters).
Choose a dry area with ambient temperature between -40 and 75 ºC (-40
and 167ºF). Operational humidity range: 5% to 95%, non-condensation
The product is open type. Be sure there is adequate airflow. (in an enclosure
or industrial panel)
The Ethernet switch should be mounted in an industrial control panel with
ambient temperature not exceeding 75 degrees C.
Connect to the Data Ports
Depending on the model, your switch can have the following ports:
EX71802-0YB
8-port 10/100BASE-TX + 2-port Gigabit
EX71622-XYB
6-port 10/100BASE-TX + 2-port 100BASE-FX + 2-port Gigabit
EX71620-XYB
6-port 10/100BASE-TX + 2-port 100BASE-FX
EX71440-X0B
4-port 10/100BASE-TX + 4-port 100BASE-FX
Apply Power
The switch has a 12-48VDC terminal block for power input. Only one power input
is required to operate the switch. However, redundant power supply functionality
is supported.
Note: Use qualified power supply, either SELV, Class 2 or double insulated per UL
60950 or UL 61010-1 or UL 61010-2-201 standards.
Device power consumption: 0.72 A
Terminal Block
The terminal block has 8 terminal posts as shown.
EX71000 Series | Hardened Managed Ethernet Switch
Switch
Pin
Description
+
12-48VDC
Power 1
Power Ground
+
12-48VDC
Power 2
-
Power Ground
Earth Terminal
Relay
Relay Output
1A @250VAC
Rating
Relay Output Alarm
The switch provides relay output contacts for signaling of a user-defined power or
port failure. The relay output can be connected to an alarm signaling device.
Current is 1A at 250VAC.
Power-Up Sequence
When the switch is powered up:
All Link/ACT LEDs blink momentarily.
The Power 1 LED light goes ON.
LEDs for every port connected to a device will flash, as the switch conducts a
brief Power On Self-Test (POST).
LED Indicators
LED
Color
State
Description
Main System
Power 1 /
On
Power on
Green
Power 2
Off
Power Off
On
Power failure
Alarm
Red
Off
No power failure
100/1000Base-TX, 100Base-FX Interface
ON = Network connection established.
Link/Act
Green
On
Flashing = port sending or receiving data.
100
Orange
On
ON = valid port connection at 100 Mbps.
1000Base-SX/LX/BX LEDs
Link/Act
ON = Network connection established.
Green
On
Flashing = port sending or receiving data.
1000
Orange
On
ON = Port connection at 1000 Mbps.
Copyright 2022 EtherWAN Systems, Inc. All Rights Reserved 12/06/2022
Installation Guide
Console Configuration
Connect to the switch console by connecting a DB-9 cable to the console
port of the switch and to the serial port of a computer running a terminal
emulation application (such as HyperTerminal or Putty).
Configuration settings of the terminal-emulator: Baud rate: 115,200bps,
Data bits: 8, Parity: none, Stop bit: 1, Flow control: none.
The default login name is "root," no password.
Web Configuration
Log in to the switch by launching a web browser and entering 192.168.1.10
in the address bar.
Enter the default login ID: root (no password) and click "Login."
Other information
DIN-Rail assembly, startup, and dismantling
Assembly: Place the Switch on the DIN rail from above using the slot. Push the
front of the Switch toward the mounting surface until it audibly snaps into place.
Startup: Connect the supply voltage to start the switch via the terminal block.
Dismantling: Pull out the lower edge and then remove the Switch from the DIN
rail.
Power wiring information:
Use cable type - AWG (American Wire Gauge) 18-24 and the corresponding
pin type cable terminals. Tighten terminal screws with a torque value of 1.7
lb-in (0.2Nm) . Do not use excessive force when fixing wiring.
Use copper conductors only
The rating of the power wire used must be at least 105°C.
W70G-EX710V2Q3 Page 1

Publicité

loading

Sommaire des Matières pour EtherWAN EX71 Serie

  • Page 1 Power Ground ▪ One console cable 12-48VDC If any items are missing or damaged, notify your EtherWAN representative. If Power 2 possible, save the carton and packing material in case you need to ship or store the Power Ground switch in the future.
  • Page 2 Link/ACT Si l'appareil est manquant ou endommagé, contactez votre représentant en charge. EtherWAN. Dans la mesure du possible, conservez le carton et le matériel Le voyant LEd s'allume. Power 1 d'emballage au cas où vous auriez besoin d'expédier ou de stocker le Remarque : Utilisez uniquement une alimentation électrique qualifiée SELV,...

Ce manuel est également adapté pour:

Ex71802-0ybEx71622-xybEx71620-xybEx71440-x0b