ECR International ADWAL Serie Manuel D'installation

Masquer les pouces Voir aussi pour ADWAL Serie:
Table des Matières

Publicité

Liens rapides

SPLIT-TYPE ROOM AIR CONDITIONER
Owner's Manual &
Installation Manual
ADWAL Series
9-24 kBtu/h
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
Please check the applicable models, technical
data, F-GAS(if any) and manufacturer information
from the "Owner's Manual - Product Fiche "
in the packaging of the outdoor unit.
(European Union products only)

Publicité

Table des Matières
loading

Sommaire des Matières pour ECR International ADWAL Serie

  • Page 1 SPLIT-TYPE ROOM AIR CONDITIONER Owner’s Manual & Installation Manual ADWAL Series 9-24 kBtu/h IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. Please check the applicable models, technical data, F-GAS(if any) and manufacturer information from the “Owner's Manual - Product Fiche ”...
  • Page 2: Table Des Matières

    Table of Contents Safety Precautions ................03 Owner’s Manual Unit Specifications and Features ............07 1. Indoor unit display.........................07 2. Operating temperature........................08 3. Other features ..........................09 4. Setting angle of airflow.........................10 5. Manual operation (without Remote)....................10 Care and Maintenance ..............11 Troubleshooting .................13...
  • Page 3 Installation Manual Accessories ..................16 Installation Summary - Indoor Unit ..........17 Unit Parts .....................18 Indoor Unit Installation ..............19 1. Select installation location......................19 2. Attach mounting plate to wall......................19 3. Drill wall hole for connective piping....................20 4. Prepare refrigerant piping.......................21 5. Connect drain hose........................21 6.
  • Page 4: Safety Precautions

    Safety Precautions Read Safety Precautions Before Operation and Installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION. CAUTION WARNING This symbol indicates the possibility of This symbol indicates the possibility of personnel injury or loss of life.
  • Page 5 CLEANING AND MAINTENANCE WARNINGS Turn off the device and disconnect the power before cleaning. Failure to do so can cause electrical shock. Do not clean the air conditioner with excessive amounts of water. Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause fire or deformation.
  • Page 6: Owner's Manual

    WARNINGS FOR PRODUCT INSTALLATION 1. Installation must be performed by an authorized dealer or specialist. Defective installation can cause water leakage, electrical shock, or fire. 2. Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire. (In North America,installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.) 3.
  • Page 7: European Disposal Guidelines

    WARNING for Using R32/R290 Refrigerant When flammable refrigerant are employed, appliance shall be stored in a well -ventilated area where the room size corresponds to the room area as specifiec for operation. For R32 frigerant models: Appliance shall be installed, operated and stored in a room with a floor area larger than 4m . Appliance shall not be installed in an unvertilated space, if that space is smaller than 4m .
  • Page 8: Unit Specifications And Features

    Unit Specifications and Features Indoor unit display NOTE: Different models have different front panel and display window. Not all the indicators describing below are available for the air conditioner you purchased. Please check the indoor display window of the unit you purchased. Illustrations in this manual are for explanatory purposes.
  • Page 9: Operating Temperature

    Operating temperature When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the unit to disable. Inverter Split Type FOR OUTDOOR UNITS COOL mode HEAT mode DRY mode WITH AUXILIARY 17°C - 32°C 0°C - 30°C 10°C - 32°C...
  • Page 10: Other Features

    Sleep Operation A guide on using the infrared remote is not The SLEEP function is used to decrease included in this literature package. Not all energy use while you sleep (and don’t the functions are available for the air need the same temperature settings to conditioner, please check the indoor display stay comfortable).
  • Page 11: Setting Angle Of Airflow

    Setting Angle of Air Flow Setting vertical angle of air flow While the unit is on, use the SWING/DIRECT button on remote control to set the direction (vertical angle) of airflow. Please refer to the Remote Control Manual for details. NOTE ON LOUVER ANGLES When using COOL or DRY mode, do not set louver at too vertical an angle for long periods...
  • Page 12: Care And Maintenance

    Care and Maintenance Rinse the filter with fresh water, then shake Cleaning Your Indoor Unit off excess water. BEFORE CLEANING OR Dry it in a cool, dry place, and refrain from MAINTENANCE exposing it to direct sunlight. ALWAYS TURN OFF YOUR AIR CONDITIONER When dry, re-clip the air freshening filter to the larger filter, then slide it back into the SYSTEM AND DISCONNECT ITS POWER SUPPLY...
  • Page 13: Maintenance - Long Periods Of Non-Use

    Maintenance – CAUTION Long Periods of Non-Use Before changing the filter or cleaning, If you plan not to use your air conditioner for an turn off the unit and disconnect its power extended period of time, do the following: supply. When removing filter, do not touch metal parts in the unit.
  • Page 14: Troubleshooting

    Troubleshooting SAFETY PRECAUTIONS If ANY of the following conditions occurs, turn off your unit immediately! The power cord is damaged or abnormally warm You smell a burning odor The unit emits loud or abnormal sounds A power fuse blows or the circuit breaker frequently trips Water or other objects fall into or out of the unit DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER IMMEDIATELY!
  • Page 15 Issue Possible Causes The outdoor unit The unit will make different sounds based on its current operating mode. makes noises Dust is emitted from The unit may accumulate dust during extended periods of non-use, which will be either the indoor or emitted when the unit is turned on.
  • Page 16 Problem Possible Causes Solution Wait for the power to be restored Power failure The power is turned off Turn on the power The unit is not The fuse is burned out Replace the fuse working Replace batteries Remote control batteries are dead The Unit’s 3-minute protection Wait three minutes after restarting has been activated...
  • Page 17: Accessories

    Accessories The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. The items are not included with the air conditioner must be purchased separately.
  • Page 18: Installation Summary - Indoor Unit

    Installation Summary - Indoor Unit 15cm (5.9in) 12cm 12cm (4.75in) (4.75in) 2.3m (90.55in) Attach Mounting Plate Select Installation Location Determine Wall Hole Position Drill Wall Hole Connect Piping Connect Wiring (not applicable for some locations in North America ) Wrap Piping and Cable Prepare Drain Hose (not applicable for some locations in North America ) STEP...
  • Page 19: Unit Parts

    Unit Parts NOTE: The installation must be performed in accordance with the requirement of local and national standards. The installation may be slightly different in different areas. Air-break switch (1) (2) Functional Filter (On Back of Remote Controller Wall Mounting Plate Main Filter - Some Units) Remote controller Holder Front Panel...
  • Page 20: Indoor Unit Installation

    Indoor Unit Installation NOTE ABOUT WALL HOLE: Installation Instructions – Indoor unit If there is no fixed refrigerant piping: PRIOR TO INSTALLATION While choosing a location, be aware that you Before installing the indoor unit, refer to the should leave ample room for a wall hole (see label on the product box to make sure that the Drill wall hole for connective piping step) model number of the indoor unit matches the...
  • Page 21 Step 3: Drill wall hole for connective piping 1. Determine the location of the wall hole based on the position of the mounting plate. Refer to Mounting Plate Dimensions. 2. Using a 65mm (2.5in) or 90mm(3.54in) Type A (depending on models )core drill, drill a Type B hole in the wall.
  • Page 22: Prepare Refrigerant Piping

    Step 5: Connect drain hose Step 4: Prepare refrigerant piping The refrigerant piping is inside an insulating By default, the drain hose is attached to the left- sleeve attached to the back of the unit. You hand side of unit (when you’re facing the back must prepare the piping before passing it of the unit).
  • Page 23: Connect Signal And Power Cables

    WARNING BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE BEFORE PERFORMING ANY ELECTRICAL REGULATIONS OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM. 1. All wiring must comply with local and national electrical codes, regulations and must be Step 6: Connect signal and power cables installed by a licensed electrician.
  • Page 24: Wrap Piping And Cables

    pen front panel of the indoor unit. 1. O NOTE ABOUT WIRING Using a screwdriver, open the wire box cover THE WIRING CONNECTION PROCESS MAY on the right side of the unit. This will reveal DIFFER SLIGHTLY BETWEEN UNITS AND the terminal block.
  • Page 25: Mount Indoor Unit

    Step 8: Mount indoor unit Connect drain hose and refrigerant piping (refer to Refrigerant Piping Connection If you installed new connective piping to the section of this manual for instructions). outdoor unit, do the following: Keep pipe connection point exposed to If you have already passed the refrigerant perform the leak test (refer to Electrical piping through the hole in the wall, proceed...
  • Page 26: Outdoor Unit Installation

    Outdoor Unit Installation Install the unit by following local codes and install unit in the following locations: DO NOT regulations , there may be differ slightly between different regions. Near an obstacle that will block air inlets and outlets Near a public street, crowded areas, or where noise from the unit will disturb others Near animals or plants that will be harmed by hot air discharge...
  • Page 27: Anchor Outdoor Unit

    Step 2: Install drain joint(Heat pump unit only) Step 3: Anchor outdoor unit Before bolting the outdoor unit in place, you must The outdoor unit can be anchored to the install the drain joint at the bottom of the unit. ground or to a wall-mounted bracket with Note that there are two different types of drain bolt(M10).
  • Page 28 Outdoor Unit Dimensions (mm) Mounting Dimensions W x H x D Distance A (mm) Distance B (mm) 681x434x285 (26.8”x 17.1”x 11.2”) 460 (18.1”) 292 (11.5”) 700x550x270 (27.5”x 21.6”x 10.6”) 450 (17.7”) 260 (10.2”) 450 (17.7”) 260 (10.2”) 700x550x275 (27.5”x 21.6”x 10.8”) 255 (10.0”) 720x495x270 (28.3”x 19.5”x 10.6”) 452 (17.8”)
  • Page 29: Connect Signal And Power Cables

    Step 4: Connect signal and power cables 7. Insulate unused wires with PVC electrical tape. Arrange them so that they do not touch any The outside unit’s terminal block is protected by electrical or metal parts. an electrical wiring cover on the side of the unit. 8.
  • Page 30 ECR Model Liquid Side mm(in) Gas Side mm(in) ADWAL09DA/ADSZ109DA Φ6.35(1/4in) Φ9.52(3/8in) ADWAL12DA/ADSZ112DA Φ12.7(1/2in) ADWAL18DA/ADSZ118DA Φ6.35(1/4in) ADWAL24DA/ADSZ124DA Φ9.52(3/8in) Φ16( 5/8in)
  • Page 31: Remove Burrs

    PIPING EXTENSION BEYOND FLARE FORM Step 2: Remove burrs Burrs can affect the air-tight seal of refrigerant Outer Diameter of A (mm) piping connection. They must be completely Max. Pipe (mm) Min. Max. removed. Ø 6.35 (Ø 0.25”) 0.7 (0.0275”) 1.3 (0.05”) Hold the pipe at a downward angle to prevent Ø...
  • Page 32 Tighten the flare nut as tightly as possible by hand. Using a spanner, grip the nut on the unit tubing. While firmly gripping the nut on the unit tubing, use a torque wrench to tighten the flare nut according to the torque values in the Torque Requirements table below.
  • Page 33: Air Evacuation

    Air Evacuation If there is a change in system pressure, refer Preparations and Precautions to Gas Leak Check section for information Air and foreign matter in the refrigerant circuit can on how to check for leaks. If there is no cause abnormal rises in pressure, which can damage change in system pressure, unscrew the cap from the packed valve (high pressure valve).
  • Page 34: Note On Adding Refrigerant

    Note on Adding Refrigerant Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 7.5m (25’). In other areas, the standard pipe length is 5m (16‘). The refrigerant should be charged from the service port on the outdoor unit’s low pressure valve.
  • Page 35: Electrical And Gas Leak Checks

    Electrical and Gas Leak Checks Before Test Run WARNING – RISK OF ELECTRIC SHOCK Only perform test run after you have completed ALL WIRING MUST COMPLY WITH LOCAL the following steps: AND NATIONAL ELECTRICAL CODES, Electrical Safety Checks – Confirm that AND MUST BE INSTALLED BY A LICENSED the unit’s electrical system is safe and ELECTRICIAN.
  • Page 36: Test Run

    Test Run DOUBLE-CHECK PIPE CONNECTIONS Test Run Instructions During operation, the pressure of the You should perform the Test Run for at least 30 refrigerant circuit will increase. This may minutes. reveal leaks that were not present during your Connect power to the unit. initial leak check.
  • Page 37 Impedance Information (Applicable to the following units only) This appliance ADWAL09DA / ADWAL12DA can be connected only to a supply with system impedance no more than 0.373 . In case necessary, please consult your supply authority for system impedance information. This appliance ADWAL18DA can be connected only to a supply with system impedance no more than 0.210 .
  • Page 38 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.
  • Page 39: Climatiseur Du Type Split

    CLIMATISEUR DU TYPE SPLIT Manuel d'Utilisateur & Manuel d’Installation ADWAL Series 9-24 kBtu/h NOTE IMPORTANTE : Lire attentivement ce manuel avant d’installer ou d’utiliser votre nouveau climatiseur. S’assurer que ce manuel est conservé pour référence ultérieure.
  • Page 40 Table des Matières Consignes de Sécurité ………………………………………………… 03 Manuel d'Utilisateur ……………………………… 07 ……………………………………………………………………………………………… 07 2. Température de fonctionnement ……………………………………………………………………………………… 08 3. Autres fonctions ………………………………………………………………………………………………………… 09 ………………………………………………………………………………………… 10 ……………………………………………………………………… 10 Entretien et Maintenance ……………………………………………… 11 Dépannage ……………………………………………………………… 13 Page 1...
  • Page 41 Manuel d’Installation Accessoires ……………………………………………………………… 16 Résumé de l’installation - Unité intérieure ………………………… 17 Pièces de l’appareil …………………………………………………… 18 Installation de l'unité intérieure ……………………………………… 19 1. Sélectionner l’emplacement de l’installation ………………………………………………………………………… 19 …………………………………………………………………………………… 19 ……………………………………………………… 20 4. Préparer la tuyauterie de réfrigérant …………………………………………………………………………………… 21 ……………………………………………………………………………………...
  • Page 42: Consignes De Sécurité

    Consignes de Sécurité Lire les Consignes de Sécurité avant l’Utilisation et l’Installation Une installation incorrecte en raison d'instructions non respectées peut causer de graves dommages ou des blessures. AVERTISSEMENT ou par ATTENTION. AVERTISSEMENT ATTENTION matériels ou de conséquences graves. AVERTISSEMENT Le présent appareil peut être utilisé...
  • Page 43: Avertissements Électriques

    Ne pas Ne pas ATTENTION Assurer que la condensation de l'eau puisse s'écouler sans entrave de l'appareil. Ne pas Ne pas Ne pas Ne pas laisser le climatiseur fonctionner pendant de longues périodes avec des portes ou des fenêtres AVERTISSEMENTS ÉLECTRIQUES tout risque.
  • Page 44: Avertissements Pour L'installation Du Produit

    AVERTISSEMENTS POUR L’INSTALLATION DU PRODUIT des dommages à l’appareil. ne pas installer l’appareil à moins de 1 NE PAS et le réinstaller. Page 5...
  • Page 45: Avertissement Pour L'utilisation De Réfrigérant R32/R290

    AVERTISSEMENT pour l'utilisation de Réfrigérant R32/R290 Les connecteurs mécaniques utilisés à l'intérieur ne doivent pas dépasser 3g/an à 25% de la pression Directives Européennes de Traitement Disposition Correcte du Produit Ne pas disposer ce produit Avis spécial Page 6...
  • Page 46 NOTE : différente. La forme réelle doit prévaloir. Panneau Avant Support de Télécommande télécommande (certaines Volet Minuterie Frais Dégivrage Marche Frais Dégivrage Marche Minuterie Frais Dégivrage Marche Minuterie Dégivrage » lorsque la fonction Dégivrage est activée. » lorsque l'unité est allumée. Minuterie »...
  • Page 47: Température De Fonctionnement

    Température de fonctionnement protection de sécurité peuvent s'activer et entraîner la désactivation de l'appareil. Onduleur Type Split POUR LES UNITÉS Mode EXTÉRIEURES AVEC d'air ÉLECTRIQUE AUXILIAIRE Lorsque la température Température recommandons fortement à tout moment pour assurer et continue. Température de refroidissement d'air Température...
  • Page 48: Autres Fonctions

    n'est pas inclus dans cette documentation. Toutes les consommation d'énergie pendant le sommeil (et ne nécessite pas les mêmes réglages de température Autres fonctions SOMMEIL lorsque vous redémarrera automatiquement avec les réglages Continuer à de remplacement et de maintenance doivent être fonctionner Température effectuées par du personnel professionnel.
  • Page 49 pour régler la direction (l’angle Télécommande pour plus de détails. à un angle trop vertical pendant une longue période. NOTE : Ne pas déplacer le volet à la main. Cela Cela peut provoquer la condensation de l'eau sur la réinitialisera le volet. réglage du volet à...
  • Page 50: Entretien Et Maintenance

    Entretien et maintenance Nettoyage de l'unité intérieure MAINTENANCE TOUJOURS ÉTEINDRE LE SYSTÈME DE faire glisser dans l'unité intérieure. Fermer le panneau avant de l'unité intérieure. MAINTENANCE. ATTENTION l'essuyer. Ne pas l'appareil. Ne pas de la poudre à polir ou d'autres solvants pour nettoyer l’appareil.
  • Page 51: Maintenance - Inspection Pré-Saison

    Maintenance - ATTENTION Longues périodes de non-utilisation Si vous prévoyez de ne pas utiliser votre climatiseur Ne pas utiliser l'eau pour nettoyer l'intérieur de l'unité intérieure. Cela peut détruire l'isolation et Activer la fonction précédent. Éteindre l'appareil et LED de votre télécommande ou appuyer 3 fois sur télécommande COMMANDE MANUELLE.
  • Page 52: Dépannage

    Dépannage NE PAS ESSAYER DE LE RÉPARER PAR VOUS-MÊME ! CONTACTER UN Problèmes courants aucune réparation. Problème Causes possibles L'appareil ne s'allume pas lorsque vous mise en arrêt. MARCHE / ARRÊT L'appareil passe du au mode VENTILATION fonctionner dans le mode précédemment sélectionné. à...
  • Page 53 Problème Causes possibles L'unité extérieure fait du L'appareil fera des sons différents en fonction de son mode de fonctionnement actuel. bruit La poussière est émise par l'unité intérieure ou celle-ci sera émise lorsque l'appareil est allumé. Cela peut être atténué en couvrant l'appareil extérieure pendant de longues périodes d'inactivité.
  • Page 54 Problème Causes possibles Solution Panne de courant L'alimentation est coupée Allumer l'appareil L'appareil ne fonctionne s'épuisent La protection de 3 minutes de l'appareil a été activée redémarrage de l'appareil La minuterie est activée Désactiver la minuterie Il y a trop ou peu de réfrigérant dans le L'appareil se démarre et du réfrigérant.
  • Page 55: Accessoires

    Accessoires Désignation des Désignation des accessoires accessoires Manuel 2 - 3 Télécommande Joint de drainage refroidissement & Scellé Support de la télécommande refroidissement & pour support de Plaque de montage la télécommande 5 - 8 Ancre (selon les (Devoir être installé 1 - 2 air principal par le (selon les...
  • Page 56: Résumé De L'installation - Unité Intérieure

    Résumé de l’installation - unité intérieure 15cm (5.9in) 12cm 12cm 12Cm 12cm (4.75in) (4.75in) 2.3m (90.55in) Sélectionner l’emplacement Déterminer la position du trou d’installation dans le mur Percer un trou de mur Connecter les tuyaux Connecter le câblage Enrouler la tuyauterie et les câbles Préparer les tuyaux de drainage STEP...
  • Page 57: Pièces De L'appareil

    Pièces de l’appareil NOTE : Disjoncteur à air Plaque de montage de mur Télécommande Panneau avant Support de télécommande Tuyau de drainage Volet Tuyau de réfrigérant NOTE SUR LES ILLUSTRATIONS différente. La forme réelle doit prévaloir. Page 18...
  • Page 58: Installation De L'unité Intérieure

    Installation de l'unité intérieure NOTE SUR LE TROU DE MUR : Instructions de l’installation - Unité intérieure AVANT L’INSTALLATION dans le mur (voir l’étape Percer un trou dans le mur pour la tuyauterie de connexion et de la tuyauterie de réfrigérant reliant les unités Étape 1 : Sélectionner l’emplacement d’installation emplacement approprié.
  • Page 59 Étape 3 : Percer un trou dans le mur pour la tuyauterie de connexion Déterminer l’emplacement du trou dans le mur en fonction de la position de la plaque de montage. Dimensions de la plaque de Type A montage. un trou sur le mur. S’assurer que le trou est percé 148mm (5,8 pouces) 237mm (9,3 pouces) Forme de l’unité...
  • Page 60: Préparer La Tuyauterie De Réfrigérant

    Étape 4 : Préparer la tuyauterie de réfrigérant Étape 5 : Connecter les tuyaux de drainage La tuyauterie de réfrigérant se trouve à l’intérieur d’un devez préparer la tuyauterie avant de la faire passer par le trou dans le mur. Basé...
  • Page 61: Travaux Electriques, Lire

    AVERTISSEMENT TRAVAUX ELECTRIQUES, LIRE TRAVAIL ÉLECTRIQUE OU DE par un électricien agréé. PRINCIPALE DU SYSTÈME. Tous les raccordements électriques doivent Étape 6 : Connecter le câble de signal Types de câbles et refuser d’installer l’appareil jusqu’à ce que le Câble d’alimentation intérieur H05VV-F ou H05V2V2-F La tension d'alimentation doit être comprise Câble d'alimentation extérieur : H07RN-F...
  • Page 62 Étape 7 : Enveloppe et câble Couverture AVERTISSEMENT l'appareil Tuyauterie de réfrigérant ÊTRE RÉALISÉ STRICTEMENT Fil de signal Tuyau de drainage DU PANNEAU AVANT DE L’UNITÉ INTÉRIEURE. paquet. Si vous placez le tuyau de drainage au dégâts d'eau. correspondante. ATTENTION éléments sont regroupés.
  • Page 63 Étape 8 : Installer l'unité intérieure Connecter le tuyau de drainage et la tuyauterie de réfrigérant (référer à la section Raccordement de la Tuyauterie de Réfrigérant de ce manuel pour Si vous avez déjà passé la tuyauterie de réfrigérant section de fuites Retirer le support ou le coin qui supporte l’appareil.
  • Page 64: Installation De L'unité Extérieure

    Installation de l'unité extérieure Installer l’unité en respectant les codes et les NE PAS installer l’appareil dans les endroits suivants entre les régions différentes. sorties d'air autres d’air salé CONSIDÉRATIONS SPÉCIALES POUR LE TEMPS EXTRÊME Instructions d'installation - Unité extérieure Étape 1 : Sélectionner l’emplacement d’installation un emplacement approprié.
  • Page 65 dimensions ci-dessous. Si le joint de drainage est livré avec un joint en Vous trouverez ci-dessous une liste des différentes (voir Insérer le joint de drainage dans le trou du plateau inférieur de l'appareil. est coincé en place face à l'avant de l'appareil. Connecter une rallonge de tuyau de drainage (non d'air Si le joint de drainage n'est pas scellé...
  • Page 66: Avertissement La Protection Des Yeux Est Recommandée En Tout Temps

    Dimensions de montage sur une plate-forme de montage en béton mural ATTENTION en un matériau de résistance similaire. Le mur doit pouvoir supporter au moins quatre fois le poids de l'appareil. pré-percés. fonction du plan des dimensions. puis remplacer les écrous. AVERTISSEMENT LA PROTECTION DES YEUX EST Soulever soigneusement l’appareil et placer ses...
  • Page 67 Étape 4 : Connecter les câbles de signal et d'alimentation retirer. AVERTISSEMENT l’eau de pluie de s’écouler dans le terminal. COUPER L'ALIMENTATION PRINCIPALE DU SYSTÈME. et le visser en place. Couverture H05VV-F ou H05V2V2-F En Amérique du Nord desserrant les 3 vis. conduit.
  • Page 68: Raccordement De La Tuyauterie De Réfrigérant

    Raccordement de la Tuyauterie de Réfrigérant ne pas l’appareil et peut entraîner une pression anormalement élevée dans le cycle de réfrigération. Cela peut provoquer Note sur la Longueur de Tuyau de descente de la tuyauterie. Max. Hauteur de Modèle <15 000 ECR Modèle Côté...
  • Page 69 Étape 2 : Enlever les bavures D’EVASEMENT de Raccordement de la Tuyauterie de Réfrigérant. Ils Diamètre extérieur Min. Max. tuyau. Tuyau Alésoir Pointer Forme d’évasement Étape 3 : Évaser les extrémités des tuyaux Tuyau Placer l'outil d’évasement sur la forme. Tourner la poignée de l'outil d'évasement dans le sens des aiguilles d'une montre jusqu'à...
  • Page 70: Utiliser La Clé Pour Pincer Le Corps Principal De La Vanne

    l'appareil. Exigences de torque ci-dessous. Desserrer nouveau. Diamètre extérieur du Dimension d’évasement d’évasement 90°±4 NE PAS UTILISER LA TORQUE EXCESSIVE Dévisser le couvercle de la vanne à garniture sur à nouveau. Répéter les étapes 3 à 6 pour le tuyau restant. UTILISER LA CLÉ...
  • Page 71: Évacuation D'air

    Évacuation d'Air Préparation et précaution L'air et des corps étrangers dans le circuit de réfrigérant peuvent provoquer une augmentation anormale de une pompe à vide et une jauge manifold pour évacuer tournant la clé d'un quart de tour dans le sens L'évacuation doit être effectuée lors de l'installation des aiguilles d’une montre.
  • Page 72 Longueur du tuyau de Réfrigérant supplémentaire purge d'air longueur standard du Pompe à vide tuyau R32 : R32 : 12g/m 24g/m R290 : R290 : 10g/m 18g/m Pompe à vide standard du tuyau R410A : R410A : 15g/m 30g/m R22 : 20g/m 40g/m ATTENTION...
  • Page 73: Avertissement - Risque De Choc Électrique

    AVERTISSEMENT - RISQUE DE Avant la Mise en service CHOC ÉLECTRIQUE CODES ÉLECTRIQUES LOCAUX ET NATIONAUX Contrôles de sécurité électrique ET DOIT ÊTRE INSTALLÉ PAR UN ÉLECTRICIEN fonctionne correctement fuites de gaz. savonneuse ou un détergent liquide sur tous les points Contrôles de sécurité...
  • Page 74: Mise En Service

    Mise en Service Instructions de Mise en Service TUYAUX Vous devez effectuer la Mise en Service pendant au moins 30 minutes. réfrigérant augmentera. Cela peut révéler des fuites qui de la télécommande pour l’allumer. MODE pour faire la tour des Veuillez reporter à...
  • Page 75: Information D'impédance

    Information d'impédance ADWAL09DA / ADWAL12DA ADWAL18DA ADWAL24DA Page 36...
  • Page 76 All specifications subject to change without notice. 2022 ECR International, Inc. 2201 Dwyer Avenue, Utica, a, NY 13501 PN 615000579 [05/01/2022] Tel. 800 325-5479 www.ecrinternational.com...

Table des Matières