Installation
Be sure that the output of the supplying source is switched off during installation. Also be sure that
no consumers are connected to the batteries during installation, to prevent hazardous situations.
Install the Charge Mate Pro not only as close as possible to the supplying source, but to the
batteries as well. The Charge Mate Pro must be installed in a well-ventilated environment, as high
currents will heat up the Charge Mate Pro. Preferably, the Charge Mate Pro should be mounted on
a flat metal surface, with the fins vertical.
Check the installation drawing for correct connection.
Use the template from the packaging to determine the exact location and screw holes for mounting
of the device.
Install the Charge Mate Pro in the positive lead between the battery banks.
Connect the negative of the battery banks to the Charge Mate Pro
Optionally you can install a remote status light to the Status output and A+.
Do not install the Charge Mate Pro directly above the batteries because of possible
corrosive sulphur fumes.
Remote switch (optional)
Optionally you can install a single pole ON-OFF-ON switch for remote operation of the Charge Mate
Pro, see installation drawing on page 2.
Remote switch functions
Switches input to 12/24 V.
ON
The battery banks are connected in parallel and bi-directional without current limit.
Switches input to 12/24 V for a short time.
PULSE
Emergency start (battery banks are connected for 30 seconds without current limit)
OFF
Switches input to Ground. The Charge Mate Pro is switched off.
Let the Switch input floating (or no switch connected).
AUTOMATIC
Default automatic mode with 40A / 90A fixed current limit.

LED indicators

The green status led is continuous lit when there is an electrical connection between A+ and B+.
The red warning led is lit when there is no electrical connection between A+ and B+.
Warning LED
Overvoltage
The voltage on A+ and/or B+ has been above 15,5/31 V for more than 1 s. The warning
1 blink
disappears when voltage drops below 15/30 V for more than 10 s.
High voltage differential
A voltage differential between A+ and B+ has been detected of more than 8/16 V for more than 2,5
2 blinks
s. The warning disappears when the voltage differential drops below 8/16 V for more than 2,5 s.
Temperature too high (75 °C / 167 °F)
This warning disappears when the temperature drops below 65 °C/ 149 °F.
3 blinks
Reverse current
Reverse current detected from B+ to A+ for more than 2s. Disappears after 20 s.
4 blinks