General Safety Information; Dimensions (Inch); General Safety Instructions - Speedaire 4ZL16A Instructions D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GENERAL SAFETY INFORMATION

Speedaire coalescing filters are designed to remove dirt particles and
condensation, oil aerosols and submicron solid particles down to 0.01
micron from compressed air by means of a coalescing filter element.
The main applications include air bearings, air conveying, high speed
air motors, pneumatic instrumentation and controls, gauging equipment,
and spray painting.
The device may only be operated in the permanent installation in
pressured air systems. Improper use or modifications to the device or
the use of its components which are not tested and approved by the
manufacturer may result in unforeseen damage.
Coalescing filters are used in a variety of air systems which may go
with air compressor, spray gun, filter, regulator, hoses, etc. Read and
understand all safety instructions and operation instructions before
using this unit. Basic safety precautions should always be followed to
reduce the risk of personal injury and/or property damage.

General Safety inStrUctionS

1. Read all safety instructions. Failure to do so may cause harm to you
and others.
2. Keep children and unauthorized persons away from the device.
Ensure that children are not able to play with the device.
3. Do not overload the device. Do not use the device for purposes for
which it is not intended.
4. Always make sure that the air line is in good condition.
5. Hose and connection should be inspected to avoid any leakage
before use.
6. Residual air in the system needs to be released before service or
repair.
7. Ensure that all connections and supply lines are rated for the required
pressure and air flows.
CAUTION
Polycarbonate bowls are not recommended for
use in atmospheres containing chemicals such
as acetone, benzene, carbon tetrachloride, gasoline, toluene and/or air
compressor systems using synthetic fire-resistant lubricants.
2
SPECIFICATIONS
Max. Inlet
Model
Max. temp.
Max. Flow
Press.
4ZL16A
150 psi
125°F
6 cfm
4ZL17A
150 psi
125°F
6.5 cfm
• Air supply must be dry enough to avoid ice formation below +35°F.
• At 150 psi inlet pressure, set pressure of 90 psi, and a 15 psi pressure drop.

DIMENSIONS (inch)

Grainger Items No.
Length (In./mm)
4ZL16A
1.63/42
4ZL17A
1.63/42
NOTE:
1.
For maximum life, use in conjunction with a general purpose air line filter equipped
with a 5-micron element.
2.
Polycarbonate bowls are not recommended for use in atmospheres containing
chemicals such as acetone, benzene, carbon tetrachloride, ethylene dichloride,
gasoline and/or air compressor systems using synthetic fire-resistant lubricants.
Element
Main
Bowl
Micron
Wt. (lbs)
Ports
Rating
1/8"
Polycarbonate
0.01 μm
0.28
1/4"
Polycarbonate
0.01 μm
0.28
Width (In./mm)
Height (In./mm)
1.45/37
4.25/108
1.45/37
4.25/108
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

4zl17a

Table des Matières