AUDIO VIDEO IP 6 PB - 10 PB DOOR ENTRY STATION
INSTALLATION
Flush mounting
Create a recess 366 mm high, 143 mm wide and 61 mm deep in the support.
Mount the base in the recess then connect the entry station.
Attach the front panel with the 8 FX teat screws (TORX) M3-10.
WARNING!!! Do not embed the bottom too deeply because when mounting the front panel, the seal of the latter
would no longer be in contact with it. This causes a rupture of the seal.
Mounting on plasterboard wall
Create a recess 361 mm high, 143 mm wide in the wall.
Mount the clamping kit (Option ref. 590.9600) on the entry station base.
Set the entry station base in the recess using the clamps then connect the entry station.
Attach the front panel with the 8 FX teat screws (TORX) M3-10.
Technical data sheet no. 604-0091D
=
53
=
=
142,5
=
=
145
=
60,5
2
www.castel.fr
=
55
=
=
53
=