Before beginning the installation, make sure all power is
off, shutting power off in breaker box to areas where downlights
are to be installed is recommended.
Required Tools (not included): Safety glasses and gloves.
1. Double check and measure the ceiling hole. Make sure it is the
correct size for outside rim of the luminaire to cover the hole while still
allowing the back of luminaire to sink in to the ceiling and springs to
hold fi rmly.
Remove existing retrofi t can if present or move it out of the way
since it will not be needed for installation.
If new hole is to be cut, use provided hole template. Place
template over the desired location. Trace the outer ring with a pen or
pencil (not included). Cut the opening with a saw (not included). (Figure
1)
Figure 1 / Figura 1 / Schéma 1
2. Open the cover of the remote driver box. Push and remove one of
the knockouts on the side plate.
Locate power supply leads from remote driver box and connect to
power source using wago connectors (provided). (Recommended wire
strip length less then 3/8")
Connect black wire to live wire, white wire to neutral wire, and
green wire with ground (as shown) and secure using wago connector.
Close the cover of the box. (Figure 2)
For Fixture with 0-10V dimming (120 - 277V driver only), use
Wirenut to connect violet dimmer wire from fi xture (+)
from dimmer and pink or gray dimmer wire ( - ) from fi xture to negative
( - ) wire from dimmer. See dimmer electrical schematic for more info.
CONNECT GROUND WIRE
USING CONNECTOR
ACCESS
(ROMEX CABLE)
NEUTRAL WIRE
(FROM POWER SUPPLY)
GROUND WIRE
(FROM POWER SUPPLY)
LIVE WIRE
(FROM POWER SUPPLY)
Figure 2 / Figura 2 / Schéma 2
3. Connect the remote driver box to the light fi xture and tighten the nut
connector by hand. Arrow on the male and female parts of the connec-
tor between the driver and fi xture cable should match. (Figure 3)
Figure 3 / Figura 3 / Schéma 3
4. Place remote driver box thru the cut-out hole.
 MUST follow local electric
MUST follow local electric code
placement of the remote driver box. (Figure 4)
STEP-BY-STEP GUIDE
to positive (+) wire
(FROM DRIVER BOX)
GROUND
WIRE
LIVE
NEUTRAL
(BARE COPPER /
WIRE
WIRE
GREEN)
(BLACK)
(WHITE)
(FROM POWER SUPPLY)
connector
NEUTRAL WIRE
GROUND WIRE
connector
LIVE WIRE
connector
"+" WIRE
(FROM 0-10V DIMMER)
"-" WIRE
(FROM 0-10V DIMMER)
THREAD
LOCK
code for rigid attachment and
Optional Mounting Kits: Instruction sheet for new construction
plate and joist bar kit can be found at www.acuitybrands.com
SIDE WALL
ATTACH USING PROVIDED
KEYHOLE FITTINGS
ROUND HEAD SCREWS
Figure 4 / Figura 4 / Schéma 4
5. Pull the spring clip on the fi xture up and through the ceiling hole
and place module in the hole making sure the spring clips are holding
securely. (Figure 5)
6. Turn the power back on. If the module doesn't illuminate within
5 seconds, turn power off, carefully remove the module and double
check all wiring and replace. (Figure 6)
Figure 6 / Figura 6 / Schéma 6
WARNING:
DO NOT PLACE YOUR HAND UNDERNEATH SPRING CLIP
DURING REMOVAL PROCESS. SNAPPING OF THE CLIPS
CAN CAUSE INJURIES TO THE HAND. (Figure 7)
FOR FIXTURE WITH
0-10V DIMMING ONLY
" + " WIRE
" - " WIRE
(PINK OR GRAY)
(VIOLET)
DO NOT
DO NOT
PLACE YOUR
PLACE YOUR
HAND
HAND
Figure 7 / Figura 7 / Schéma 7
connector
DO NOT USE ANY OTHER DRIVER EXCEPT LITHONIA LIGHT
connector
ING DRIVER THAT IS INCLUDED WITH THE FIXTURE.
DO NOT CONNECT MULTIPLE MODULES TO ONE DRIVER.
DO NOT OPEN THE MODULE AND SIDE PLATE OF THE
REMOTE DRIVER BOX - NO SERVICEABLE PARTS INSIDE.
Trouble Shooting Guide
If this fi xture fails to operate properly, use the guide
below to diagnose and correct the problem. 
 Verify that fi xture is wired properly.
 
 Verify that fi xture is grounded correctly.
 Verify that the line voltage at the fi xture is correct.
If further assistance is required, contact:
Technical Support at: (800) 748-5070
This LED module does not require service or new bulbs to
change.