If the fork can't be pumped up to its rated highest position, you may
have to add hydraulic oil into the oil tank. The hydraulic fluid to be
used must have a quality of ISO VG22 or equivalence.
Mixing of different fluids is prohibited!
Trouble Shooting Guide
Items
Symptom
1
Fork cannot
be pumped
up.
2
Fork can't be
released
down.
3
Fork can't be
pumped up to
rated highest
position.
E/D/E GMBH · EDE PLATZ 1 · 42389 WUPPERTAL · GERMANY
Possible Cause
1. Low oil level in
oil tank.
2. Air in the hydraulic
system.
3. Pendulum arm nut
is not adjusted
properly.
Fork blocked.
1. Pendulum arm nut
not adjusted
properly.
Oil is not enough.
Aliments
1. Add proper hydraulic
oil.
2. Fast operating the
handle for several
times. Bleed the
system.
3. Adjust
pendulum arm
screw. (See picture 2)
1. Check and remove
the block.
2. Adjust pendulum arm
nut properly.
(See picture 2.)
Add hydraulic oil.
(See picture 3.)