6.

Electrical connection

6.1
Loosen the cheese-head screw (a) and pull it out halfway.
6.2
Pull the coupler socket (b) from the solenoid coil (c).
6.3
Pull the cheese-head screw (a) out fully.
6.4
Remove the plastic cover (d).
6.5
Take out the connection diagram (e).
6.6
Pull out the rectifier card (f) and the connector insert (g).
12 V AC and 24 V AC connections
Caution!
Operate the solenoid self-closing valve for 12 V AC and 24 V AC with safety extra
low voltage (SELV). Before connecting, check the specified operating voltage. Do
not earth the components.
6.7
Connect the low-voltage cable to terminals (u) and (v) on the rectifier card.
230 V AC connection
6.8
Connect the mains lead.
L1: Phase conductor
N: Neutral conductor
PE: Protective earth conductor
6.9
Assemble and mount the coupler socket in the reverse order.
7.

Function

7.1
Setting the operating mode.
a: Electric operation
b: Manual operation
8.

Replacing the Filter

8.1
Close the gate valve.
8.2
Close the water volume regulator with an Allen key.
8.3
Remove the locking screw.
8.4
Replace the filter.
6