Télécharger Imprimer la page

Suncourt In-Line Duct Fan Serie Instructions D'installation

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLATION INSTRUCTIONS FOR IN-LINE DUCT FANS™
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INSTRUCTIONS
WARNING – RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH: DISCONNECT AND/OR LOCKOUT ALL REMOTE ELECTRIC POWER SUPPLIES BEFORE
SERVICING OR INSTALLING. WHEN THE SERVICE DISCONNECTING MEANS CANNNOT BE LOCKED, SECURELY FASTEN A PROMINENT WARNING DEVICE,
SUCH AS A TAG TO THE SERVICE PANEL.
WARNING – USE COPPER SUPPLY WIRES ONLY.
WARNING – FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. DO NOT USE TO
EXHAUST AIR LADEN WITH LINT, GREASE, OR OIL.
WARNING – PRODUCT INTENDED INSTALLATION IS AN INLINE DUCT FAN WITH BOTH ENDS CONNECTED TO DUCTWORK (SEE INSTALLATION INSTRUCTIONS
SECTION). FOR ANY OTHER INSTALLATION, GUARDS MUST BE INSTALLED TO PREVENT UNINTENTIONAL CONTACT WITH MOVING FAN BLADE UNLESS THE
UNIT IS MOUNTED WITH THE LOWEST MOVING PARTS AT LEAST 2.4M (8FT) ABOVE FLOOR OR GRADE LEVEL.
WARNING – FAN IS SUITABLE FOR ONLY CONNECTION TO A DUCT SUPPLYING SINGLE-ROOM DISCHARGE (MODELS: DB100C, DB200C, DB204C, DB205C,
DB206C, DB208C, DB306E, DB308E)
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. You may phone the manufacturer during normal business
hours at 1-800-999-3267 or submit your questions from our website: www.suncourt.com.
In-Line Duct Fans
are designed to boost dry conditioned (heated or cooled) indoor airflow in ducts of forced air systems with temperatures between 40°F (4°C) and 140°F
TM
(60°C). Suncourt accepts no responsibility for use of this product in other applications.
EXPOSURE TO AIRFLOW TEMPERATURES EXCEEDING 140°F (60°C) WILL PERMANENTLY DAMAGE THE FAN AND VOID THE WARRANTY.
ELECTRICAL SAFETY INSTRUCTIONS
WARNING – To Reduce the Risk Of Fire, Electrical Shock, or Injury to Persons, Observe the Following:
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction and
accessibility.
Your In-Line Duct Fan
must be connected to a 110/120 Volt AC, 60Hz fuse or circuit breaker protected power source only in a manner approved by all applicable codes. Never
TM
connect your In-Line Duct Fan
to a 240 Volt AC blower motor or other 240 Volt AC system. Never connect your In-Line Duct Fan
TM
For a two-speed In-Line Duct Fan
TM
The power source must be protected by a fuse or circuit breaker rated at a minimum of 15 amperes.
You may also supply power to your In-Line Duct Fan
For In-Line Duct Fans
without power cord attached, all connections to the power supply must be made inside the electrical box provided with the unit. Use power supply
TM
conductors and wire nuts of appropriate size and type. Attach a wire nut to any unused lead in a 2-speed In-Line Duct Fan
ground wire properly terminated at the fan (green wire).
For In-Line Duct Fans
with power cord attached, the cord can be plugged in to any standard (NEMA 5-15) 3-prong outlet. The outlet supplying power to the cord must include a
TM
ground terminal properly connected to a ground source. The power cord should be secured to a location where it is not subject to damage, abrasion, or temperatures exceeding
140°F (60°C).
GENERAL INSTALLATION NOTES
For maximum performance and minimum noise, the best location to install your In-Line Duct Fan
To prevent air leaks, use a good quality aluminum foil duct tape to seal the seams in the ductwork after installing the In-Line Duct Fan
By utilizing tapered reducers, you may install larger diameter duct fans in smaller diameter ducts to achieve greater boosted airflow.
Always leave your In-Line Duct Fan
ACCESSORY INFO
Ductstat
Temperature Sensitive Switch
®
The In-Line Duct Fan
can be controlled by our Ductstat
TM
into the Ductstat
and set the controls to operate the fan only when conditioned air is sensed inside the boosted duct. Please visit www.suncourt.com for more info on the
®
Ductstat
Temperature Sensitive Switch
®
Standard Variable Speed Control, model VS100
The speed of your non-corded In-Line Duct Fan
utilizes solid-state circuitry to safely adjust the fan speed without damaging the motor. The speed control mounts inside a standard 2x4 electrical box and includes a cover plate
and mounting hardware.
WARNING – NEVER USE A RHEOSTAT OR LIGHT DIMMER SWITCH TO CONROL YOUR FAN SPEED. A SOLID-STATE SPEED CONTROLLER MUST
BE USED TO AVOID DAMAGE TO THE MOTOR.
Please visit www.suncourt.com for more info on these or other accessories.
INSTALLATION INSTRUCTIONS
In-Line Duct Fans
with power cord attached have the model number extension DBxxxC
TM
In-Line Duct Fans
with electrical box attached have the model number extension DBxxxE
TM
MODEL: DB100C
1. Locate the place in the duct where you wish to install the In-Line Duct Fan™.
2. Tape the enclosed template to the duct with the arrow pointing in the direction of the airflow. Cut out the required opening by first drilling a pilot hole and cutting
along the dashed line using a jig saw or tin snips.
3. Place the Inductor® In-Line Duct Fan™ in the opening, making sure that the fan blade can turn freely. Align the arrow on the unit in the direction of airflow.
4a. Connect the spring through the middle hole provided in the base plate, stretch the spring over the duct and through the middle hole on the other side of the
loose plate. Bend the ends of the spring over to secure, providing a snug installation.
4b. Secure the In-Line Duct Fan™ in position with the supplied #6 sheet metal screws using the provided holes in the base plate of the unit.
5. Finish the installation by covering the seams in the duct with a good quality aluminum foil duct tape.
, never connect directly to multiple taps on the furnace blower; always use isolation relays.
using the Suncourt DuctStat
TM
accessible for maintenance, cleaning, or repair.
TM
, model DS100
TM
to operate the fan. This is the easiest way to interlock your In-Line Duct Fan
®
.
TM
(models DB412E, DB414E, DB416E) can be controlled with our model VS100 Variable Speed Control. This speed control
TM
Temperature Sensitive Switch
or a standard on/off switch (Purchased Separately).
®
TM
is 6–10 feet from the register that needs the boosted air.
TM
to a variable-speed (ECM) furnace blower.
TM
. The power supply wiring must always include a
TM
.
TM
to your furnace. Simply plug your fan
TM

Publicité

loading

Sommaire des Matières pour Suncourt In-Line Duct Fan Serie

  • Page 1 Simply plug your fan ® into the Ductstat and set the controls to operate the fan only when conditioned air is sensed inside the boosted duct. Please visit www.suncourt.com for more info on the ® Ductstat Temperature Sensitive Switch ®...
  • Page 2: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Suncourt Inc. recommends that you clean your In-Line Duct Fan™ at regular intervals, similar to what is recommended for the fan of your furnace, no less than twice a year. Keep your In-Line Duct Fan™ free of lint, dust, and debris. The In-Line Duct Fan™ must never be exposed to temperatures over 140°F (60°C).
  • Page 3 Utilisez cet appareil uniquement de la manière prévue par le fabricant. Si vous avez des questions, contactez le fabricant. Vous pouvez téléphoner au fabricant pendant les heures normales de bureau au 1-800-999-3267 ou soumettre vos questions sur notre site web: www.suncourt.com.
  • Page 4: Conduit Métallique

    Veillez-vous pour relier le fil coloré comme montré ci-dessous. Le manque de se relier correctement détruira le moteur. Assurez-vous d'attacher un serre-fils à n'importe quel fil inutilisé. Aucune réclamation de garantie pour un moteur inexactement de câble ne sera acceptée par Suncourt.
  • Page 5: Nettoyage Et Entretien

    GARANTIE D’UN AN Sous réserve des limitations suivantes, Suncourt Inc. (le fabricant) garantie le ventilateur In-Line Duct Fan™ contre tout défaut de pièce et de main d'oeuvre pour une période d'un (1) an à partir de la date d'achat original, mais n'excédant pas deux ans à partir de la date de fabrication. Cette garantie est sous réserve des limitations suivantes: (a) la responsabilité...

Ce manuel est également adapté pour:

In-line duct fan db412eIn-line duct fan db414eIn-line duct fan db416eIn-line duct fan db306eIn-line duct fan db308eIn-line duct fan db310e