Broan HLB3 Instructions
Masquer les pouces Voir aussi pour HLB3:
Table des Matières
Les langues disponibles

Les langues disponibles

Liens rapides

MODEL HLB3
IN-LINE BLOWER
For use with Broan Elite and NuTone Premier Hoods.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper-
corn Beef Flambe').
C. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels -
violent steam explosion will result.
!
FOR DOMESTIC COOKING ONLY
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "TYPICAL INSTALLATION"
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (straight-through blower discharge)
- Wiring
• "MOUNTING OPTIONS"
• "WIRING OPTIONS"
- Wiring Plate Position
• "DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (vertical blower discharge)
• "USE AND CARE"
• "SERVICE PARTS"
• "WARRANTY"
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
Page 1
!
Table des Matières
loading

Sommaire des Matières pour Broan HLB3

  • Page 9 Page 9 MODÈLE HLB3 VENTILATEUR MONTAGE DANS LIGNE Pour usage avec Broan Elite et NuTone Premier hottes de cuissine. LIRE ET CONSERVER CES INSTRUCTIONS POUR USAGE DOMESTIQUE SEULEMENT AVERTISSEMENT AVERTISSEMENT 4. Utilisez un extincteur SEULEMENT si: POUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUE OU DE A.
  • Page 10: Installation Typique

    Page 10 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) MONTAGE EN UTILISANT LE KIT DE CINTRE (inclus) CONDUIT CIRCULAIRE DE 10 po (25,4 cm) TRANSITION CIRCULAIRE DE 8 à 10 po (20,32 à 25,4 cm) CONDUIT CHARPENTE VIS ET CIRCULAIRE SUPPLÉMENTAIRE DE RONDELLE...
  • Page 11: Options De Câblage

    Page 11 CÂBLAGE OPTIONS DE CÂBLAGE NOIR AU POSITION DE LA DESSUS / NOIR ARRIÈRE DU PLAQUE DE CÂBLAGE BOÎTIER FIL DE TERRE À PLAQUE DE CÂBLAGE BRANCHEMENT DU CÂBLE D’ALIMENTATION PLAQUE À LA VERTICALE CÂBLAGE BRANCHEMENT DU ENTRÉE CÂBLE D’ALIMENTATION BLANC 120 VCA À...
  • Page 12: Utilisation Et Entretien

    Cette garantie vous donne des droits légaux spécifiques et il se peut que vous ayez d’autres droits. Cette garantie annule toutes les garanties précédentes. Pour le service sous garantie, vous devez (a) aviser Broan-NuTone á l'adresse ou numéro de téléphone mentionnée ci-dessous, (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la nature de tout défaut dans le produit ou la pièce.

Table des Matières