Télécharger Imprimer la page

IFM Electronic ecomat100 CR2031 Mode D'emploi page 7

Systèmes de contrôle-commande

Publicité

Les langues disponibles

Les langues disponibles

Control systems
CR2031
Digital outputs
PWM outputs
Current outputs
Control parameters
Free wheel diodes
Climatic test
Mechanical resistance
Immunity
to conducted interference
Immunity
to interfering fields
Interference emission
Tests for railway applications
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
8 semiconductor outputs; short-circuit and overload protected
Switching voltage
10...32 V DC
Switching current
max. 4 A
Total current
max. 16 A
The current measurement of 2 channels each can be selected by means of the wire
connections. The following channels are combined: 1+2, 3+4, 5+6, 7+8
With the configuration as "PWM output" two outputs each are combined
(1+2, 3+4, 5+6, 7+8).
PWM frequency
20...250 Hz
Pulse duty factor
50...1000 ‰
Resolution
1 ‰
Switching current
max. 4 A
Total current
max. 16 A
With the configuration as "current-controlled output" two outputs each are combined
(1+2, 3+4, 5+6, 7+8).
PWM frequency
20...250 Hz
Control range
20...1000 mA / 80...4000 mA
Control resolution
1 mA / 4 mA (see control parameters)
Setting resolution
1 mA
Control characteristics
can be set via the object directory (see control parameters)
Accuracy
± 2% FS
Switching current
max. 4 A
min. 12 / 3 Ω (at U
Load resistance
min. 24 / 6 Ω (at U
By indicating the max. load current [mA] for each output pair the respective control
or value range (1000 or 4000 mA) is automatically selected.
In addition the P/I behaviour of the current controller can be parameterised for each
output pair.
Free wheel diodes for the deactivation of inductive loads are integrated
Test standards and regulations
Damp heat to EN 60068-2-30, test Db
(≤ 95% rel. humidity, non-condensing)
Salt mist test to EN 60068-2-52, test Kb, severity level 3
Protection test to EN 60529
Vibration to EN 60068-2-6, test Fc
Shock to EN 60068-2-27, test Ea
Bump to EN 60068-2-29, test Eb
to ISO 7637-2, pulses 2, 3a, 3b, 4, severity level 4, function state A
to ISO 7637-2, pulse 5, severity level 1, function state A
to ISO 7637-2, pulse 1, severity level 4, function state C
according to UN/ECE-R10 at 100 V/m (E1 type approval)
and DIN EN 61000-6-2 (CE)
according to UN/ECE-R10 (E1 type approval)
and DIN EN 61000-6-3 (CE)
EN 50155 clause 12.2 mechanical/climatic tests
EN 50121-3-2
EMC noise emission and noise immunity
additional information on request
We reserve the right to make technical alterations without prior notice.
Characteristics of the outputs
= 12 V DC)
B
= 24 V DC)
B
11.07.2022
CR2031 / page 3