Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Accessories
Art. 2313
Remote relay for VX2300 system
87,5 mm
Fig. 1
DESCRIPTION
Remote relay for VX2300 system.
All entrance panels on the VX2300 system include the lock re-
lease relay and push to exit button input inside the entrance
panel. For higher security applications including installations in
compliance with 'Secured By Design' the 2313 enables the relay
and push to exit button input 1 to be installed in a secure loca-
tion away from the entrance.
There is also a second relay that can be activate pressing the
service button present in every VX2300 phone or videophone.
MOUNTING INSTRUCTIONS
1. Remove the terminal side covers by unscrewing the retaining
screws (Fig. 3).
2. Fix the device to a DIN rail (Fig. 4) or directly to the wall using
two expansion type screws (Fig. 5).
3. Isolate the mains using the circuit breaker mentioned above
then make the connections as shown on the installation dia-
grams (if provided).
4. Check all connections and secure the wires into the terminals;
5. When all connections are made replace and fix the terminal
covers with the relevant screws (Fig. 6).
6. Restore the mains.
Art. 2313 - Installation instructions
66 mm
A
B
A
LEGEND
A
B
C
D
Fig. 3
Fig. 5
- 1 -
Fig. 2
Connection terminals covers
Dip-switch cover
Connection terminals
8 way dip-switch
C
C
1
2
Fig. 4
Fig. 6
66251215 - V1.0 - 01/06/22
D

Publicité

Table des Matières
loading

Sommaire des Matières pour Videx 2313

  • Page 1 For higher security applications including installations in 8 way dip-switch compliance with ‘Secured By Design’ the 2313 enables the relay and push to exit button input 1 to be installed in a secure loca- tion away from the entrance.
  • Page 2 Nr.8 Setting Up ON OFF ON OFF = 2 seconds OFF OFF ON ON = 8 seconds ON OFF ON OFF = 16 seconds OFF ON ON = 32 seconds - 2 - Art. 2313 - Installation instructions 66251215 - V1.0 - 01/06/22...
  • Page 3: Accessories

    5 module A type DIN box DIN bar or directly to the wall Dry contacts relay: Max 24Vac/dc 5A Power supply: Supplied by the BUS line Working temperature: -20 +60°C - 3 - Art. 2313 - Installation instructions 66251215 - V1.0 - 01/06/22...
  • Page 4: Istruzioni Di Montaggio

    Morsetti di connessione ni di sicurezza più elevate, comprese le installazioni conformi Dip-switch a 8 vie a “Secured By Design”, l’Art. 2313 consente di installare il relè e il pulsante push-to-exit ingresso 1 in un luogo sicuro lontano dall’entrata. È presente inoltre un secondo relè che può essere attivato pre- mendo il pulsante di servizio presente in ogni posto interno VX2300.
  • Page 5 OFF = 2 secondi ON OFF ON ON = 8 secondi OFF OFF ON OFF = 16 secondi ON OFF ON ON = 32 secondi OFF ON - 5 - Art. 2313 - Istruzioni di installazione 66251215 - V1.0 - 01/06/22...
  • Page 6: Specifiche Tecniche

    Contenitore DIN tipo A 5 moduli Barra DIN o a muro Relè contatti puliti Max 24Vac/dc 5A Tensione di lavoro: Fornita dal BUS Temperatura di lavoro: -20 +60°C - 6 - Art. 2313 - Istruzioni di installazione 66251215 - V1.0 - 01/06/22...
  • Page 7: Smaltimento

    DISPOSAL In accordance with the Legislative Decree no. 49 of 14 March 2014 “Implementation of the Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The crossed-out bin symbol on the equipment or on the packaging indicates that when the product reaches the end of its lifetime, it must be collected separately from mixed municipal waste.
  • Page 8 MANUFACTURER VIDEX ELECTRONICS S.P.A. FABBRICANTE Via del Lavoro, 1 FABRICANT 63846 Monte Giberto (FM) Italy FABRICANTE Tel (+39) 0734 631669 FABRIKANT Fax (+39) 0734 632475 www.videx.it - info@videx.it FABRICANTE ‫ال� ش كة المص ن ِّ عة‬ CUSTOMER SUPPORT VIDEX ELECTRONICS S.P.A.

Table des Matières