Télécharger Imprimer la page

Sagola DM 300 Manuel D'utilisation page 47

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 99
46/47
In the case of any breakdown during the guarantee period, deliver this to the nearest Technical
Assistance Service or get in touch with the factory.
Any demand of greater importance against the supplier, in particular compensation for damages,
is excluded. This is also applicable to any damages that might arise during counselling, while
acquiring practice and during demonstration.
Consequently, the services rendered under guarantee do not involve an extension of the warranty
period.
The manufacturer reserves the right to make technical modifications.
18. Disposal
For complete and correct disposal of the equipment, when it has reached the end
of its useful life, it must be completely dismantled so it can be recycled, separating
the metal and plastic components.
19. Troubleshooting
MALFUNCTION
Product comes out
the air exhaust
Air bubbles in the
product outlet
The pump stops
when expelling air
from the exhaust
CAUSE
Broken membrane
Membrane screw insufficiently
tightened or damaged seal
Suction tube insufficiently
tightened
Damaged membrane screw flat
seal
Membrane screw insufficiently
tightened
Damaged vessel joints in the
distributor
Damaged distributor plate
and/or insert
Damaged sleeve and/or anchor
bolt
O-rings damaged
O-rings of the anchor bolt
(No.9 Fig.1) damaged
ENGLISH
REPAIR
Replace membrane
Dismantle and tighten or
replace
Tighten
Tighten or replace
Tighten
Replace
Replace
Replace
Replace
Replace with new seals

Publicité

loading

Produits Connexes pour Sagola DM 300

Ce manuel est également adapté pour:

Dm 1/300Dm 400Dm 1/400