Gram TCamel S Série Manuel D'utilisation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

pen, respectively, to "E-" of A, B, C, D. At last, with eight multimeter
debugged, disconnect multimeter.
3. Insert monitor's plug then begin to demarcate.
4. After the demarcation, put "the weight on the front", middle, and back of
the fork respectively to see whether the show value is the same, if not,
adjust slightly Group C and Group D on the wiring board, do as follows:
If the value is wrong when put on the front of the fork, adjust "D +" of
Group D, clockwise for small and counterclockwise for large.
If the value is wrong when put on the back of the fork, adjust "C +"
of Group C, clockwise for small and counterclockwise for large. Until
the value is the same.
Note: This adjustment method is available when there is little error, if not,
don't use this method. You Should check whether the sensors are intact and
loose, make sure fork and fork legs are not rubbed and so on. Also when the
value is not accurate, adjust only C group and D group at the wiring board, or
A group and B group on the potentiometer, otherwise, it cannot be adjusted
correctly.
12
 

Publicité

Table des Matières
loading

Produits Connexes pour Gram TCamel S Série

Table des Matières