Select a heater installation location where the outlet air is not directed at an adjacent wall.
A. Radial Diffuser:
1. Loosen sheetmetal screws located in the side of the heater cabinet to free directional louvers. Do not remove. Reference
Figure 1 below for location.
2. Remove directional louvers and retighten sheetmetal screws from step 1.
3. Using the 8 supplied sheetmetal screws, mount radial diffuser in prepunched holes located in the heater cabinet as shown in
Figure 2.
4. Adjust louvers to direct airflow as desired.
B. Anemostat Diffuser:
1. Remove sheetmetal screws and directional louvers as shown in Figure 1.
2. Remove front cabinet panel. See Figure 3 for attachment screw locations.
3. Using the supplied bolts, nuts and lock washers, install anemostat diffuser into the prepunched holes in front panel.
4. Reinstall front heater cabinet panel.
INSTALLATION INSTRUCTIONS-
DIFFUSER ACCESSORY KITS
240 Series Electric Unit Heater
Accessory kit installations should be performed by a qualified electrician.
Disconnect all power supplies before working on equipment.
Heater KW Rating
(Reference heater nameplate)
<= 5KW
5< KW <= 20
KW > 20
WARNING
Radial
Diffuser Kit
HX-1024152
HX-1024153
HX-1024154
Anemostat
Diffuser Kit
HX-1024155
HX-1024156
HX-1024157
HX24-2241-83EF

Publicité

loading

Sommaire des Matières pour Heatrex 240 Serie

  • Page 1 INSTALLATION INSTRUCTIONS- DIFFUSER ACCESSORY KITS 240 Series Electric Unit Heater WARNING Accessory kit installations should be performed by a qualified electrician. Disconnect all power supplies before working on equipment. Select a heater installation location where the outlet air is not directed at an adjacent wall. Heater KW Rating Radial Anemostat...
  • Page 2 Instructions d’installation des necessaires accessoires de diffuseur pour les appareils de chauffage série 240 AVERTISSEMENT L’installation des necessaires accessoires ne devraient executées que par des électriciens qualifiés. Débranchez tous circuits alimentaires avant de faire des changements à l’équipement. Choissisez un endroit pour l’installation de l’appareil de chauffage où l’air d’échappement ne soit pas dirigé...

Ce manuel est également adapté pour:

Hx-1024152Hx-1024153Hx-1024154Hx-1024155Hx-1024156Hx-1024157