H-4176
WALL-MOUNT FLAMMABLE
STORAGE CABINET
TOOLS NEEDED
5/16" (8 mm)
Socket Wrench
#12 - 2⁄" TEK Screw x 2
Self-Tapping Screw x 2
NOTE: To ensure safety in facilities, it's important to eliminate the chance of an electrostatic discharge
while handling flammable fluids.
CAUTION! If user will dispense Class 1 flammable liquids from a container held within safety cabinet, ground
the cabinet. As an industry best practice, it is recommended to ground the cabinet when dispensing Class 2
combustible liquids if the liquids are near, at, or above the liquid's flashpoint temperature. Be aware of these
external and internal grounding considerations.
1.
For exterior cabinet grounding, locate the safety
cabinet's ground screw just below the green dot on
the right-hand side. (See Figure 1)
Figure 1
PAGE 1 OF 9
Electric Drill
1/8" Drill Bit
1/4" Drill Bit
Bolt x 3
GROUNDING INSTRUCTIONS
Ground
Screw
1-800-295-5510
uline.com
PARTS
Washer x 3
Nut x 3
2. Use a 5/16" (8 mm)
wrench or nut driver to
loosen screw.
(See Figure 2)
Attach the ground wire
and retighten screw.
Para Español, vea páginas 4-6.
Pour le français, consulter les pages 7-9.
Internal Tooth
Lockwasher x 3
Spacer x 2
Ground Screw
Connection
Figure 2
1221 IH-4176

Publicité

loading

Sommaire des Matières pour Uline H-4176

  • Page 1 Para Español, vea páginas 4-6. Pour le français, consulter les pages 7-9. H-4176 1-800-295-5510 uline.com WALL-MOUNT FLAMMABLE STORAGE CABINET TOOLS NEEDED 5/16" (8 mm) Electric Drill 1/8" Drill Bit Socket Wrench 1/4" Drill Bit PARTS #12 - 2⁄" TEK Screw x 2...
  • Page 2 NOTE: The information contained herein was continuity through prepared by the manufacturer and is provided metal-to-metal contact as a service to our customers. Uline is not of ground wires. responsible for the accuracy or completeness (See Figure 4) of this information.
  • Page 3 (See Figure 7) NOTE: Check for applicable regulations and local codes. Determine load support and capabilities of wall. 1.0737" Cabinet Bottom View Cabinet #12 - 2⁄" TEK Screw Wall Figure 7 1-800-295-5510 uline.com PAGE 3 OF 9 1221 IH-4176...
  • Page 4 H-4176 800-295-5510 uline.mx GABINETE PARA ALMACENAMIENTO DE INFLAMABLES DE PARED HERRAMIENTAS NECESARIAS Llave de Dado de Taladro Broca de 1/8" 5/16" (8 mm) Eléctrico Broca de 1/4" PARTES 2 Tornillos TEK #12 de 2⁄" 3 Rondanas de 3 Pernos 3 Rondanas...
  • Page 5 NOTA: Esta información fue preparada por el tierra. fabricante y se proporciona como un servicio (Vea Diagrama 4) Diagrama 4 a nuestros clientes. Uline no es responsable de la precisión o integridad de esta información. INSTRUCCIONES DE INSTALACIÓN Instale pernos, rondanas, rondanas de seguridad Diagrama 5 y tuercas en el soporte de instalación (centre...
  • Page 6 NOTA: Verifique las regulaciones y los códigos locales aplicables. Determine el soporte de 1.0737" carga y las capacidades de la pared. Vista Inferior del Gabinete Gabinete Tornillo TEK #12 de 2⁄" Pared Diagrama 7 800-295-5510 uline.mx PAGE 6 OF 9 1221 IH-4176...
  • Page 7 H-4176 1-800-295-5510 uline.ca ARMOIRE DE RANGEMENT IGNIFUGE – FIXATION MURALE OUTILS REQUIS Clé à douilles de Perceuse Mèche de perceuse 8 mm (5/16 po) électrique de 1/8 po Mèche de perceuse de 1/4 po PIÈCES Vis TEK nº 12 - 2 ⁄ po x 2...
  • Page 8 REMARQUE : Les présentes informations sont Figure 4 rédigées par le fabricant et sont fournies à nos clients à titre de service. Uline n'est pas responsable de l'exactitude ou de l'exhaustivité de ces informations. INSTRUCTIONS DE MONTAGE...
  • Page 9 REMARQUE : Vérifiez les réglementations et les codes locaux en vigueur. Déterminez la 1,0737 po capacité de charge du mur. Vue du dessous de l'armoire Armoire Vis TEK nº 12 - 2 ⁄ po Figure 7 1-800-295-5510 uline.ca PAGE 9 OF 9 1221 IH-4176...