Troubleshooting
Overload error
Possible cause
Head lock up holding force exceeded during CMM acceleration
Collision with workpiece or CMM
Obstruct error
Possible cause
Head / stylus configuration obstructed
Probe extension combination too long
Internal head fault
PH10 PLUS head and non-PLUS PHC10-3 or third party controller
Datum error
Possible cause
Cable / connections faulty
Head / stylus configuration obstructed
Probe extension combination too long
Head damaged
Issued 12 2021
Solution
Reduce mass of probe combination.
Reduce acceleration.
Check head for damage.
Remove obstruction and repeat move.
Solution
Check head for damage.
Remove obstruction and repeat move.
Use a shorter / lighter stylus combination.
Contact your Renishaw representative.
Contact your Renishaw representative.
Solution
Check condition of cabling from head to controller.
Remove obstruction and update head using HCU2 or under CMM
control.
Use shorter / lighter stylus combination.
Contact your Renishaw representative.
32