FIBARO FGCD-001 Instructions D'installation page 12

Masquer les pouces Voir aussi pour FGCD-001:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
WHAT YOU HEAR
4 x BEEP
every 5s
1 x BEEP
2 x BEEP
every 60s
3 x BEEP
every 60s
3 x BEEP
every 30s
1 x BEEP
1 x BEEP
1 x BEEP
1 x BEEP
12
WHAT YOU SEE
4 x RED BLINK
every 5s
1 x YELLOW BLINK
every 30s
2 x YELLOW BLINK
every 60s
3 x YELLOW BLINK
every 60s
1 x BLUE BLINK
every 30s
1 x WHITE BLINK
1 x GREEN BLINK
every 60s
1 x GREEN BLINK
after powering
1 x RED BLINK
after powering
1 x MAGENTA BLINK
CYAN BLINKING
WHAT IT MEANS
DETECTED
PRESENCE OF
CARBON
MONOXIDE WHICH
CAN KILL YOU!
Low battery level
Sensor error,
DOES NOT DETECT
CARBON MONOXIDE
End of lifespan
Heat alarm
Tamper alarm
Device powered
Added to Z-Wave
Not added
to Z-Wave
Out of range
Firmware update
WHAT TO DO
1. Open windows
2. MOVE TO
FRESH AIR!
3. Contact emer-
gency services
Replace battery
Reset device,
replace if no effect
Reset device,
replace if no effect
Be cautious of fire
Check housing
Check Z-Wave
Wait for completion

Publicité