Operating Conditions - Eaton 3S 550 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8

Operating conditions

This product is an Uninterruptible
l
Power Supply (UPS) for computers
and their peripherals, television
sets, stereo systems and video
recorders... It must not be used to
supply other electrical equipment
(lighting, heating, household
appliances, etc.).
UPS connections
Connect the UPS 1 to the
l
AC-power system via a wall outlet
with an earth connector, using the
attached cord for a UPS with FR/
DIN sockets or with the supply cord
of your computer for a UPS with
IEC sockets (see figure A).
Plug critical equipment
l
(computer, monitor, modem,
etc.) into the outlets 6 providing
battery backup power and surge
protection (see figure B), taking
care not to exceed the rated current
indicated in amperes.
Other devices (printer, scanner,
l
fax, etc.) can be connect to the
filtered outlets 5 that provide
surge protection (see figure B). The
filtered outlets are not backed up
by battery power in the event of a
power outage.
Optional Internet modem /
l
Network connection:
A modem or Ethernet data line
can be protected against surges by
connecting it via the UPS. Connect
the existing device cable between
the wall outlet and the UPS, and
use a similar cable between the
UPS and the device, as indicated in
figure C (cable not supplied).
Optional USB connection:
l
The UPS devices can be connected
to the computer using the USB
cable 4 supplied.
Download software at
l
powerquality.eaton.com.
Register warranty at
l
powerquality.eaton.com.
6
Operation
5 : Filtered outlets.
6 : Battery backup outlets.
7 : LED ON indicate a UPS fault.
8 : ON/OFF button for the battery
backup outlets.
9 : Protection circuit breaker.
9
5
Battery charge: The UPS
l
charges the battery as soon as it is
connected to the AC outlet, whether
button 8 is pressed or not. When
used for the first time, the battery
will only provide its maximum
autonomy after it has been charged
for 8 hours. It is recommended that
the UPS be permanently connected
to the AC power supply to ensure
the best possible autonomy.
Switching-on the UPS: press
l
button 8 for about 1 second.
Filtered outlets 5 without
l
battery backup: Equipment
connected to these outlets is
supplied as soon as the AC cord is
plugged in. They are not affected by
button 8 .
Battery backup outlets 6 :
l
Equipment connected to these
outlets is supplied as soon as
button 8 turns green (see figure
E). These outlets can be turned on
even if the UPS is not connected to
AC power (button 8 flashes).
AC-power disturbance: If AC
l
power is disturbed or fails, the UPS
continues to operate on battery
power. Button 8 flashes green.
In normal mode, the audio alarm
beeps every five seconds, then
every two seconds when the end of
battery backup time is near.
If the power outage lasts longer
l
than the battery backup time, the
UPS shuts down and automatically
restarts when power is restored.
Following a complete discharge, a
few hours are required to recharge
the battery back to full backup time.
To save battery power, it is
l
possible to press button 8 to cut
the supply of power to the devices
connected to the battery backup
outlets.
Lightning protection: All outlets,
l
whether backed up or simply
filtered, include surge protection,
whatever the position of button 8 .
Shutdown of the battery backup
l
6
outlets 6 : Press button 8 for
more than two seconds.
Battery disposal and safety
Caution. Battery service life is
l
reduced by 50 % for every ten
8
degrees above 25 °C.
7
The battery elements must be
l
replaced exclusively by qualified
personnel (risk of electrocution),
with new elements approved by
EATON to ensure correct operation
of the UPS.
The battery must be disposed
l
of in accordance with applicable
regulations. To remove the battery
elements, shut down the UPS
(button 8 OFF), remove the power
cord and proceed as indicated in
page 4 "Battery change".

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3s 700

Table des Matières