Installation instructions CMP
ENG
CMP is designed to fit in wallbox and give out a selectable control signal of 0/1-10Vdc.
the CMP can be controlled by one or more retractive push buttons. A short press for on/off and a
longer press for dimming up or down, the opposite of last longer push.
CMP keeps the memory during power failure.
Wiring (see wiring diagram figure 1)
a) Set the intended behavior of the control signal output (0/1-10V).
Check "Setting output control signal" below.
b) Connect the incoming phase to the input labeled L.
c) Connect the incoming zero/null to the input labeled N.
d) Connect the push button between phase (L) and input marked S.
e) Note that the push button shall only release current when pushed.
f) Connect the output marked L 'into phase on the ballast to be controlled if you want CMP to
remove voltage from the controlled driver. this means that the prospective driver has zero in
standby consumption.
g) Connect the plus and minus outgoing control signal labeled 0/1-10V to the drivers 0/1-10V
input, plus to plus and minus to minus.
h) Verify that everything is correct. When uncertain about point d) and/or e) concerning the
controlled drivers wiring, please refer to the manual of the intended driver.
i)
turn the power on.
Setting output control signal
the output of the CMP can be set in three different types. this is done by using the DIP switch on
the back of the CMP (see Figure 2). Set the DIP switch according to the table below.
DIP-setting
Output voltage Output voltage at off
(DIP 1-2)
ON ON
1-10V
(factory setting)
ON OFF
1-10V
OFF ON
0-10V
Specifications
Designation
Part number
Input
Degree of protection
Size
Weight
Power consumption (230V)
Primary maximum breaking power (230V)
Output 0/1-10V control range
Output minimum voltage
Output 0/1-10V max capacity
Output signal curve
Vadsbo LightTech
Aröds Industriväg 34
SE-422 43 Hisings Backa
Sweden
V
= V
: the current adjusted signal level (1-10Vdc) is
OFF
ON
kept intact even when switched off.
Switching off the load may be done via internal relay and L'.
V
< 10mV: the signal settles below 10mV.
OFF
Can in fact be regarded as closed since the output signal
moves between 1-10V.
Switching off the load may be done via internal relay and L'.
V
< 20mV: the signal settles below 20mV.
OFF
Can in fact be regarded as closed since the signal moves
between about 50mV-10V.
Switching off the load may be done via internal relay and L'.
CMP
V-40010DCP
220-240 Vac
IP20 (for indoor use)
Ø57x22 mm
71 g
1W
10A
0-10V/1-10V +-40mV
I
< 10mA: V
sink
OUt
I
< 10mA: V
sink
OUt
50mA
1-10V: 2,25V / s
1-10V: 2,25V / s
Phone +46-31-235600
Fax
+46-31-226010
E-mail info@vadsbo.net
Web
www.vadsbo.net
, min = 13mV
, min = 13mV
Driver
figure 1
figure 2
Rev 2015-01-12