PROTEC5X - User's manual
4.4
Zones operating
The four protection zones have different operating features.
4.4.1

Zone 1 (delayed)

On system enabled, the opening of NC line activates an alarm cycle, after the entering
!
time setted in programming (par. 3.5).
The time of the alarm cycle is setted in programming.
!
If the NC line is not restored it autoexcludes after 3 alarm cycles.
!
At the restoring of the NC line the zone is reincluded in service.
!
It can be exclued by the user by the button on the front panel or by electronic key.
!
It is advisable to use this zone for the NC lines made by magnetic contacts placed on the
entrance door/s. The entering time allows to enter from these entrances and to arrive at the
central unit to disable the system. If an SKI connector is installed outside of the entrance door, it
is advisable to program the minimum enering time.
4.4.2
Zone 2 (immediated)
On system enabled, the opening of NC line activates an alarm cycle.
!
The time of the alarm cycle is setted in programming.
!
If the NC line is not restored it autoexcludes after 3 alarm cycles.
!
At the restoring of the NC line the zone is reincluded in service.
!
It can be exclued by the user by the button on the front panel or by electronic key.
!
It is advisable to use this zone for the NC lines made by volumetric detectors . The
possibility to disable this zone by panel or electronic key, will allow the partial system operating
(ex. in the night zones giving the possibility to move liberally in the rooms leaving the others
protection zonesenabled).
4.4.3
Zone 3 (immediated)
On system enabled, the opening of NC line activates an alarm cycle.
!
The time of the alarm cycle is setted in programming.
!
If the NC line is not restored it autoexcludes after 3 alarm cycles.
!
At the restoring of the NC line the zone is reincluded in service.
!
It can be exclued by the user by the button on the front panel or by electronic key.
!
It is advisable to use this zone for the NC lines made by magnetic contacts.
4.4.4
Zone 24h (immediated)
On system disabled, the opening of NC line activates a continuous alarm cycle. It will stop
!
at the line restoring.
On system enabled, the opening of NC line activates an alarm cycle.
!
The time of the alarm cycle is setted in programming.
!
46