Lbl.
Description
CP
Compressor parameters
diF
Differential
HSE Max. temp. allowed setpoint
LSE Min. temp. allowed setpoint
Ont
ON time if faulty room sensor
OFt
OFF time if faulty room sensor
dOF Time between comp. OFF and next start
dbi
Time between 2 compresor starts
dEF Defrost parameters
dtY
Defrost operating mode: 1=gas 0=electric
dit
Time interval between 2 defrosts
dCt
Defrost interval time count mode
dEt
Defrost time override
dSt
Defrost Termination Temperature
FAn Fans parameters
FSt
Fans stop temperature
Fdt
Fans ON delay
dt
Drain Down Time
dFd
Fans OFF during defrost
FCO Fans ON during compressor OFF
Fod
Fans OFF during door open
AL
Alarms parameters
AFd
Alarm differential
HAL High temperature alarm setpoint
LAL
Low temperature alarm setpoint
PAO Alarm delay after start-up
dAo
Alarm delay after defrost
OAO Alarm delay after door opening
SA3 High temperature alarm setpoint
dA3
Differential
PrE
Pressure alarms parameters
PEn Number of pressure trips
PEI
Time period for pressure trips
diS
Display parameters
CA1 Calibration room sensor
dro
Selection Celsius/Farenheit (0 = °C, 1 = °F)
Dispay during the defrost
ddL
(0=normal read, 1=read block,2=diplay deF)
CnF Configuration parameters
PA2 password setting according second level

PARAMETER LIST

2SCH106 2SCH107 2SCH108 2SCH109
Medium
Low
hot
hot
gas
gas
2
2
10
-15
-5
-25
10
10
20
20
2
2
2
2
1
1
3
3
0
0
20
20
15
15
50
50
3
3
2
2
Y
Y
n
n
n
n
2
2
5
5
-5
-5
3
6
60
60
1
1
55
55
2
2
10
10
60
60
0
0
0
0
0
0
/
/
Medium
Low
electric
electric
2
2
10
-15
-5
-25
10
10
20
20
2
2
2
2
0
0
3
3
0
0
30
30
8
8
50
50
3
3
2
2
Y
Y
n
n
n
n
2
2
5
5
-5
-5
3
6
60
60
1
1
55
55
2
2
10
10
60
60
0
0
0
0
0
0
/
/
UM
°/1
°/1
°/1
min
min
min
min
num
hours
num
min
°/1
°/1
min
min
flag
flag
flag
°/1
°/1
°/1
hours
min
hours
°/1
°/1
Num
min
°C
flag
flag
flag