CAUTION!
A completely discharged Battery will be blocked against deep discharge
If the battery reaches a capacity of 33% during charging (two LEDs
light up, Fig. F), discharging is possible again in normal operation.
Charging Process
The display is activated during the
charging process. New battery packs
reach full capacity after approx. 5 charging
and discharging cycles. Recharge battery
packs that have not been used for a long
time before use. It is not possible to charge
the battery pack outside the permissible
temperature values. The battery pack
charger will then display an error. If the
display does not show anything during the
charging process, refer to the Error table
below.
Operation
1 Slide the battery pack into the holder of
the unit.
2 Remove the battery pack from the unit
after use.
3 Charge partially discharged battery
packs after use.
Storage
Store battery packs indoors only with low
humidity and below 20 °C (68°F).
The battery pack display switches off
automatically during storage.
Note:
New battery packs must be
fully charged before they are
used for the first time. This
cancels the transport mode
of the battery pack.
Note:
The charging socket of the
rechargeable battery pack is
located under the flap (Fig. A,
area 3).
CAUTION:
Loose Battery Pack
Loose battery packs may
result in risk of injury and
damage.
Ensure that the battery pack
snaps into place.
CAUTION
Humidity and Heat
Humidity and heat can cause
risk of damage and limited
storage time,recharging may
be necessary.