Towel Warmer Installation Procedure
STEP 1
Rough-in Requirements (see figure 3)
1. A 110V receptacle located no further than 18" from
electric plug-in exit location on towel warmer (see fig.
2), and not above electric plug-in exit location.
2. Wall studs or plywood backing is required in the wall at
all bracket locations. See figure 2 for bracket locations.
STEP 3
STEP 3
Electric Plug-In Connection
Electric Plug-In Connection
Do not connect the Towel Warmer to the power supply until all instructions have been read and installation carried out in accord
Do not connect the Towel Warmer to the power supply until all instructions have been read and installation carried out in accord
with them. The heating element is 150W / 300W / 450W 110V. The element conforms to UL standards and the unit to CSA
with them. The heating element is 150W / 300W / 450W 110V. The element conforms to UL standards and the unit to CSA
standards (File ref: 229718). Ensure the CSA label is visible.
standards (File ref: 229718). Ensure the CSA label is visible.
1. Turn off power supply.
1. Turn off power supply.
2. Plug connector in.
2. Plug connector in.
3. Switch on power supply again.
3. Switch on power supply again.
Warning: In case of damage or failure of the Towel Warmer the unit should be returned to the manufacturer or their distributor.
Warning: In case of damage or failure of the Towel Warmer the unit should be returned to the manufacturer or their distributor.
The warranty of 2 year on the heating element and lifetime on the Towel Warmer is NOT VALID in case of improper use or
The warranty of 2 year on the heating element and lifetime on the Towel Warmer is NOT VALID in case of improper use or
installation. Product is designed for use within Canada and the United States only.
installation. Product is designed for use within Canada and the United States only.
Figure 1
STEP 2
Installation Instructions (see figure 1)
1. Check all items have been received. You should have
received a towel warmer and mounting bracket kit.
Read all instructions before continuing.
2. Fix wall supports "B" including collar "A" to the wall
using the screws provided and in locations as shown on
figure 2.
3. Screw the threaded pin "C", into the threaded bushing
"D" on the back of the towel warmer.
4. Hang and adjust the towel warmer using set screws "E"
to lock pin "C" in the wall bracket "B". Ensure the towel
warmer is firmly and safely fixed.