INSTALLATION INSTRUCTIONS
ELECTRICAL SHOCK HAZARD
WARNING
Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box). Failure to do so could result in serious
injury or death. Only qualified electricians should install this fixture and the installation MUST conform to the Canadian
Electrical Code Part I and all local codes and ordinances. Ensure that only proper tools, materials, and equipment are used to
complete the installation.
SAFETY
Proper grounding is required to ensure personal safety.
Fixture should be mounted in locations where unauthorized personnel will not readily subject it to tampering.
Do not use this equipment for anything other than its intended purpose.
Servicing this equipment should be performed by qualified service personnel.
Save these instructions.
MIN 90 °C SUPPLY CONDUCTOR
TOOLS
Allen key set, open-end wrench, phillip screwdriver, Drilling tool
(optional).
INSTALLATION
Slip Fitter:
1.
Attach the slip fitter mount to the fixture using two M12 bolts
provided.
2.
Attach both handles on either side to the fixture and slip fitter using
two M8 bolts provided.
3.
Remove the fixing bolts and cover from the slip fitter.
4.
Run the supply and dimming wires through the slip fitter from top to
bottom.
5.
Loosen the four locking bolts on the slip fitter, connect the wires to
the supply wires as per the wiring diagram, and then attach the
fixture on top of the pole.
6.
Fasten the locking bolts between slip fitter mount and the pole to
secure the fixture.
7.
Loosen the adjusting bolts and tilt the fixture to required angle.
Fasten the adjusting bolts after the angle is confirmed, and reattach
the cover using fixing bolts.
Note: Adjustable angle is 0-90°.
READ, UNDERSTAND
before installing the equipment.
FOLLOW
, and
these instructions

Publicité

loading

Sommaire des Matières pour RAB Design SFL2-LED

  • Page 1 SFL2-LED INSTALLATION INSTRUCTIONS READ, UNDERSTAND FOLLOW , and these instructions ELECTRICAL SHOCK HAZARD before installing the equipment. WARNING Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box). Failure to do so could result in serious injury or death.
  • Page 2 Connect fixture WHITE wire to power supply NEUTRAL wire. • Connect fixture BLACK wire to power supply LINE wire • The fixture includes 0-10V dimming functionality, connect PINK and PURPLE wires to a 0-10V dimming controller (optional). Page 2 of 4 RAB Design Lighting inc. May - 2022...
  • Page 3 Une fois l'angle obtenu, fixez les boulons de réglage et remettez le couvercle au moyen des boulons de montage. Note : Le réglage de l'angle est de 0 à 90° Page 3 of 4 RAB Design Lighting inc. May - 2022...
  • Page 4 Connectez le fil NOIR du luminaire au fil LIGNE de l'alimentation • Le luminaire inclut une fonction de gradation 0-10V, connectez les fils GRIS ou ROSE et VIOLET à un gradateur 0- 10V (en option). Page 4 of 4 RAB Design Lighting inc. May - 2022...