P/N 92254301 • Rev A ECN 20-051 • 12/15/2020
PMT Series
Pole Mounted Terminal
Installation Note
CAUTION: The Product shall be installed in a manner to comply with applicable national and local safety codes.
ATTENTION : Le produit doit
applicables en matière de sècuritè.
SAFETY: Verify no hazardous voltages exist on lines while making connections.
SÈCURITÈ : Vèrifiez qu` aucunes tensions dangereuses existent sur les lignes lors des connexions.
NOTE: IN SOME UNITS THE STUB WILL HAVE EXCESS WIRE PAIRS. THE STUB SHOULD
ALWAYS BE WIRED STARTING WITH PAIR 1.
Description
The PMT Series are unprotected pole mounted
terminal units with air dammed input stubs. Customer
drop connections are made using Tii's ADX Modules
that provide dual ports for each line for ease of wiring.
Both ports utilize tool-less IDC rockers.
1.
The upper ports accept AWG 22-24 wire, and are
terminated using a finger actuated rocker paddle.
2.
The lower ports terminate AWG 18.5-24 wire and
are terminated by a drive bolt.
3.
The ADX modules are equipped with integral
sealed test points for ease of troubleshooting.
Installation
1. Mount the installation bracket to the pole using ¼-
20 screws or lag bolts according to your company's
standard practice. (Figure 1).
être installè
de manière à se conformer aux règlementations nationales et locales
Figure 1
2. Loosen four side nuts and hang the terminal on
installation bracket. Tighten side nuts to secure it
to the bracket (Figure 2).
Wire Termination
Upper Rocker (22/24 AWG solid copper wires only):
1. Cut the appropriate length of 22/24 AWG wire.
2. Do not strip wire insulation. Make certain wire ends
are cut flush with insulation.
3. Lift rocker to full upright position, insert wires,
confirm wires are fully inserted (Figure 3).
4.
Lower rocker to full down position to terminate.
Figure 2

Publicité

loading

Sommaire des Matières pour Tii technologies PMT Serie

  • Page 1 P/N 92254301 • Rev A ECN 20-051 • 12/15/2020 PMT Series Pole Mounted Terminal Installation Note CAUTION: The Product shall be installed in a manner to comply with applicable national and local safety codes. ATTENTION : Le produit doit être installè de manière à...
  • Page 2 After terminating wire in the rocker, place wire thought wire loop and grommet in the housing (Figure 5). Figure 3 Lower Port (large gauge wires or wires with hard insulation): 1. Cut the appropriate length of 18.5 / 24 AWG wire. 2.
  • Page 3 Note pour installation ATTENTION : Le produit doit être installé en conformité avec les codes de sécurité nationaux et locaux. SÉCURITÉ : Avant les connexions, s’assurer de l’absence de toute tension dangereuse. NOTA : POUR CERTAINS TERMINAUX, LE TRONÇON D’ENTRÉE PEUT COMPORTER DES PAIRES EN TROP. TOUJOURS AMORCER LE CÂBLAGE PAR LA PAIRE 1.
  • Page 4 Bornes inférieures (fils de plus fort calibre ou fils à isolant rigide) : 1. Couper le fil de calibre 18.5 / 24 AWG à la longueur appropriée. 2. Ne pas dénuder le fil. S’assurer que le fil et son isolant sont coupés ras. 3.