PROBLEM
2. Excessive dirt on
glass
3. Glass bleaching or
colour fading of the
plate
4. Poor heating
5. Venting smoke and /
or gases from the front,
bad smell
6. Excessive draft
7. Poor draft
CAUSE
Incorrect duct
Inappropriate fuel
Overly closed registers
Excessive
temperature
excessive
heat
in
chamber
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong
position
First lighting
Flammable or combustible items in the
enclosure or surrounding walls of the
equipment
Crack in the combustion chamber of the
equipment
Incorrect duct
Combustion control registers in the wrong
position
Incorrect duct
Duct dirtiness
SOLUTION
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
caused
by
Check the fuel load avoiding overheating
the
combustion
Adjust registers
Use recommended fuel
Adding fuel
Adjust registers
Wait for the polymerization process of the
paint to finish; this can take from one to
several lightings.
Review of insulating materials such as
fiberglass, fireproof wood or any inflammable
elements and replace them.
Check for tightness and if you discover a
crack, please contact your dealer.
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
Open the primary and secondary register
following the steps outlined in the manual.
Should this not have an effect, check that the
flue duct is clean; if it is not clean, contact a
professional to clean this. If the problem
persists contact your dealer.