  • Page 1 Installation Guide Models: JVEC-ULP May be covered by the following United States and International Patents: D631148S, 138172, 001790452-001, 338608 and other patents pending jetventfans.com JetVent is a Registered Trademark...
  • Page 2 WARNING: To reduce the risk of fire, electric shock, and injury to persons, JetVent Fans must be installed only with controllers supplied by ZOO Fans.
  • Page 3 WARNING: Do not flex or bend the blades or fan brackets when installing, adjusting, or cleaning the fan. Do not insert foreign objects in between rotating fan blades. CAUTION – HOT SURFACE. Avoid being burned. When fan is turned off use caution when touching motor surfaces to be sure they have cooled sufficiently.
  • Page 4 (il) est conformément à tous les codes pertinents. AVERTISSEMENT: Pour réduire le risque d'incendie, de choc électrique et de blessures, JetVent Fans doivent être installés uniquement avec des régulateurs fournis par les ZOO Fans. D'autres pièces ne peuvent être substituées — elles peuvent causer des blessures et annuleront les garanties du produit.
  • Page 5 AVERTISSEMENT: Ne pas faire fonctionner le ventilateur dans des espaces présentant des matières dangereuses ou explosives et des vapeurs. DANGER: Equipement rotatif. La mort, les blessures graves et les dommages matériels peuvent résulter. • Les grilles de sécurité du ventilateur doivent rester solidement fixées. •...
  • Page 6: Table Des Matières

    STEP 1: HANGING THE FAN ................................... 3 STANDARD INSTALLATION METHOD ..............................3 SOUND SENSATIVE INSTALLATION ..............................3 JetVent Fans Do’s and Don’ts: ................................4 STEP 2: WIRING FAN MAINS ................................. 5 STEP 3: WIRING FAN SPEED CONTROL SIGNAL ............................. 6 OPTION 1 - Wiring 0–10 Volt DC Analog Signal ..........................
  • Page 7: Pre-Installation

    PRE-INSTALLATION The safe installation and operation of equipment supplied by Zoo Fans is the responsibility of the system designer, installer, maintainer, and operator (collectively, the “User”). The need for protective safety accessories to meet company standards, applicable codes, and the requirements of the Occupational Safety and Health Act (“OSHA”) must be determined by the User since safety requirements may vary depending on the location and application of the equipment.
  • Page 8: Jetvent Fans Specifications

    You may also contact your Zoo Fans’ representative or Zoo Fans directly if you require assistance. Remember, the number of JetVent Fans required for the job, as well as where they are hung, will depend on a number of variables, some of which are: •...
  • Page 9: Installation

    INSTALLATION STEP 1: HANGING THE FAN Mounting Points are illustrated in Red. Two sets of holes are provided on the unit, one is a 13mm hole to be used for mounting directly via hanger rods or bolts, and the other is a 25mm Hole to support the fan with anti-vibration mounts (close up of yellow box Illustrated on the right).
  • Page 10: Jetvent Fans Do's And Don'ts

    JetVent Fans Do’s and Don’ts:...
  • Page 11: Step 2: Wiring Fan Mains

    STEP 2: WIRING FAN MAINS The JetVent JVEC-ULP fans are equipped with EC motors that will accept a range of voltages. See below: 208 – 277 Volts 1-Phase 50/60 Hertz Alternatively, these motors will accept DC voltage. Please contact Zoo Fans for details. •...
  • Page 12: Step 3: Wiring Fan Speed Control Signal

    STEP 3: WIRING FAN SPEED CONTROL SIGNAL The JetVent Fans have multiple speed control options available including: 0 – 10 Volt DC analog signal MODBUS RS-485 (must be preconfigured at factory) WARNING: Never apply line voltage to the digital input Contact Zoo Fans for other speed control options.
  • Page 13: Option 2 - Wiring Modbus Control Signal

    OPTION 2 - Wiring MODBUS Control Signal Fieldbus/Modbus Communication Cabling The controller is able to communicate using Modbus RTU (RS485) to JetVent Fans, Vacon Variable Speed Drives (VSDs), and fieldbus sensors. Devices must be connected in a daisy chain with the controller at the start of the chain. No star connections are §...
  • Page 14 The shield must always be connected to the Ground (GND) terminal at each device. § Avoid unsheathing the communications cable for an excessive length (>20cm) § The shield must NEVER be connected to an electrical protective earth point § Termination Communication cables must be terminated with 120 ohm ¼...