Transport, storage and packaging

3.1
General transport instructions
Check on delivery for completeness and transport damage.
Proceed as follows in the event of visible damage:
Do not accept delivery or only accept with reservations.
Record any transport damage on the transportation documents or on the transport company's
delivery note.
Submit a complaint to the freight forwarder.
IMPORTANT NOTE!
Warranty claims can only be made within the applicable period for complaints.
(More information is available in the T&Cs on the Kampmann website)
4

Installation and wiring

IMPORTANT NOTE!
Ensure that the unit is horizontal and maintain minimum clearances!
Only position the unit on a horizontal, stable base surface with a minimum clear-
ance of 15 cm to the rear and to the wall at the side! Leave 50 cm clear in front
of the air inlet and outlet to guarantee optimum operation of the unit.
Position of the unit
KA-520 L / XL
KA-520 XXL
Position standing
Bond the felt glider
on site!
recommendation:
Adhering floor castors to the underside of the unit
5
Electrical connection area of KA-520 L
KA-520 L / XL: The air purifier
can be used standing upright or
lying horizontally. Attach the
felt gliders supplied to the un-
derside of the unit to prevent
damage to the floor!
KA-520 XL Pro / XXL: The ad-
justment feet or rolls supplied
must be screwed into the un-
derside of the unit!
Electrical connection area of KA-520 L
1
Beispielbild Luftreiniger L
Commissioning
1
2
3
5
6
4
3
1
2
Luftreiniger KA-520
Assembly instructions
Attach floor castors pre-as-
1
sembled on metal plates
(accessory) to the underside of
the unit.
Remove the protective film
from the adhesive strips and
press the plates onto the un-
derside of the unit as shown
max.
in the figure.
Commissioning the KA-520
L
Insert the connection cable
supplied into the mains
3
socket
, then into the
power socket.
Use the main switch
2
switch on the unit.
Select the required operating
level
1
:
I: low power
II: high power, e.g. for tem-
porary flushing of the room
Commissioning the KA-520
Insert the connection cable
supplied into the mains
7
socket
1
, then into the
power socket.
2
Use the main switch
switch on the unit.
Select the required operating
4
stage I
(low power) or II
3
(high power, e.g. for
temporary flushing of the
room): Refer to the adhesive
label on the back for further
8
information on the status
lights
5 6 7
and timer
operation.
Operation video: