Télécharger Imprimer la page

Immergas C9 Notice D'instructions page 10

Masquer les pouces Voir aussi pour C9:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

General warnings.
All Immergas products are protected with suitable
transport packaging.
The material must be stored in a dry place
protected from the weather.
This instruction manual provides technical
information for installing the Immergas kit. As
for the other issues related to kit installation (e.g.
safety at the workplace, environmental protection,
accident prevention), it is necessary to comply with
the provisions specified in the regulations in force
and with the principles of good practice.
Improper installation or assembly of the Immergas
appliance and/or components, accessories, kits
and devices can cause unexpected problems for
people, animals and objects. Read the instructions
provided with the product carefully to ensure
proper installation.
Installation and maintenance must be performed
in compliance with the regulations in force,
according to the manufacturer's instructions and
by professionally qualified staff, meaning staff
with specific technical skills in the plant sector, as
envisioned by the law.
Kit composition:
Ref. Qty Description
1
1
Door adaptor Ø 125
2
1
Door gasket made of neoprene
3
4
Screws 4.2 x 9 AF
4
1
Hex headed screw M6 x 20
5
1
Flat nylon washer M6
6
2
Door hole closure metal-sheet plate
plug
7
1
Plug gasket made of neoprene
8
1
Toothed washer M6
9
1
Nut M6
10
1
Concentric gasket Ø 60-100
11
1
Flanged adapter Ø 80-125
12
4
Hex headed screws M4 x 16 slotted
-
1
Bag of lubricating talc
Kit Description.
This kit allows an Immergas boiler to be installed
in "C93" configuration, with combustion air
intake directly from the shaft where the flue
gas exhaust is, obtained by means of a ducting
system.
The kit is suitable for the installation of
condensation boilers only, approved for such
application.
Attention: the boiler must be installed
exclusively with an original Immergas "Green
Series" air intake and flue extraction plastic
device.
The plastic pipes cannot be installed outdoors, for
tracts longer than 40 cm, without suitable protection
from UV rays and other atmospheric agents.
This flue can be identified by an identification
mark and special distinctive marking bearing
the note "only for condensation boilers".
System composition.
This kit must be combined with the following
components (sold separately) to be functional
and complete:
- Rigid Ø 80 ducting kit.
- Flexible Ø 80 ducting kit.
- Flexible Ø 50 ducting kit.
Supplied separately:
Ref. Qty Description
A
1
Ducting kit door
12
12
11
10
IE
IE IE
2
1
3
3
3
7
6
5
4
10
- flue exhaust kit Ø 80/125 configured according
to the installation and type of boiler.
KIT ASSEMBLY.
Proceed as follows to assemble the kit:
- Mount the components of kit "C9" on the door
(A) of the ducting system (Fig. 1).
- Mount the flanged adaptor (11) interposing the
concentric gasket (10) on the boiler, fitting it
with the screws (12).
- Mount the ducting system as described in the
relative instructions sheet.
- Calculate the distances between the boiler
drain and the bend of the ducting system.
- Prepare the boiler flue system, making sure
that the internal pipe of the concentric kit
Ø 80/125 is fitted up to the end stop in the
ducting system curve (Quota "X" Fig. 2),
whereas the external pipe must reach the end
stop of the adapter (1).
N.B.: to encourage the removal of possible
condensate forming in the exhaust pipe, tilt
the pipes towards the boiler with a minimum
slope of 1.5%..
Installation drawings key:
Unique identification of the component
1
in the kit
Identification of the component not sup-
A
plied in this kit
6 8
A
9
Fig. 1

Publicité

loading

Ce manuel est également adapté pour:

3.022033