Télécharger Imprimer la page

BEL TET4000-48-069RA Serie Instructions D'installation page 2

Publicité

2
SAFETY APPROVALS
Approved to the latest edition of the following standards:
UL/CSA 62368-1, IEC 62368-1 and CE Mark.
INSTALLATION
For details and mechanical drawings, access the AC-DC Data Sheet/App Notes link on the website at www.belfuse.com/power-solutions and go
to the respective TET4000 listing.
CAUTION
These component level power supplies are intended exclusively for installation within other equipment by an industrial assembly operation or by
professional installers. These are Class 1 power supplies; the unit must be properly connected to earth ground in end use. A component power
supply should be installed in end-use equipment according to the requirements of the safety standard used for that equipment. This power supply
is not designed to be operated outside of an enclosure which provides a means of mechanical, electrical, and fire protection. To maintain SELV/ES1
requirements, the outputs should not be connected together in any manner which causes the total output voltage to exceed 60 VDC.
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take
adequate measures.
PROTECTIVE EARTHING
The Power Supply must be properly grounded to mains protective earth termination at end use.
FUSING
CAUTION: DOUBLE POLE/NEUTRAL FUSING. Fuses F1 and F2 are rated 30 A, 500 V (fast acting).
ENVIRONMENTAL CONDITIONS:
TRANSPORTATION & STORAGE:
Ambient Temperature Range:
Relative Humidity Range:
Altitude:
OPERATION:
Ambient Temperature Range:
Relative Humidity Range:
Altitude, People's Republic of China (PRC):
Altitude, other countries:
* For the details about power derating check the product datasheet.
OPTIONS based on P/N Suffix:
Blank
Standard PSU
AC INPUT = only 200 – 250 V
S441
V1: 54.5 V
, 73 A max.
H, S510 
AC INPUT = 100-127V
DC INPUT = 240 – 380 V
-40 ° C to +70 ° C
5% to 95% RH Non-Condensing
to 10 000 m ASL
0° C to +45° C (at 4060 W load)*
+45° C to +55° C (at 3060 W load)*
10% to 90% RH Non-Condensing
仅适用于海拔 2000m 以下地区安全使用
to 4000 m ASL*
INSTALLATION INSTRUCTION
AC
INPUT:
DC
OUTPUT
S:
, 200 – 277 V
, 22 A
Note: Input selection is automatic; no manual change is
required.
200 – 250 V
, 25 A, 50/60 Hz
100 – 127 V
, 25 A, 50/60 Hz
V1: 48 – 58 V
, 83 A max.
V2: 12 V
, 5 A
Maximum Output Power: 4060 W
tech.support@psbel.com