Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Model
DVP20CC30(-1,-2)
This conversion kit is to be installed by an Empire Comfort Systems, Inc. distribu tor (or other
qualified agency
)* in accordance with the manufac turer's instruc tions and all codes and
1
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition), Natural Gas and Propane Installation Code,
1
CSA B149.1
*The term "qualified agency" means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is responsi ble for (a) the installation
of gas piping or (b) the connection, installation repair, or servicing of equipment, who is
experienced in such work, familiar with all precau tions required, and has complied with all the
requirements of the authority having jurisdic tion.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
CHECK SAFETY SHUTDOWN SYSTEM
Continuous Ignition Systems (Standing Pilot)
1. Place gas control knob in PILOT position. Main burner should go off and pilot should remain lit.
2. Extinguish pilot flame. Pilot gas flow should stop within 30 seconds. Safety shutoff of pilot gas proves complete
shutdown since safety shutoff valve blocks flow of gas to main burner and pilot.
3. Relight pilot burner and operate system through one complete cycle to make sure all controls operate properly.
41331-1-0220
GAS CONVERSION INSTRUCTIONS
DIRECT - VENT GAS FIREPLACE
CONVERSION KITS
Part No.
31052
FOR CONVERSION TO PROPANE GAS
CHECK THE SAFETY SHUTDOWN PERFORMANCE
Empire Comfort Systems Inc. • Belleville, IL
Model
DVP30CC30(-1,-2)
WARNING
WARNING
Part No.
31058
Page 1

Publicité

loading

Sommaire des Matières pour Empire DVP20CC30-1

  • Page 1 31058 FOR CONVERSION TO PROPANE GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc. distribu tor (or other qualified agency )* in accordance with the manufac turer’s instruc tions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
  • Page 2 24. Replace the log shelf and secure to the rear wall by replacing BAFFLE the two screws removed in step 7. 25. Replace logs per instruction in Owner’s Manual. 26. Place glass frame onto firebox and attach two door latches to bottom of firebox. 27. The converted appliance must be connected to a supply of the conversion gas and checked for leaks at all connections. 28. The appliance must be checked to ensure it is operating at the correct pressure of 10.0" w.c. 29. Conversion is completed. Figure 1 Page 2 Empire Comfort Systems Inc. • Belleville, IL 41331-1-0220...
  • Page 3 VERIFYING INPUT RATE OF CONVERTED FIREPLACE The input of the fireplace must be checked as follows: 1. Turn off all other gas appliances. Clock the gas meter and determine the number of seconds required to consume one cubic foot of gas. 2. 3600 ÷ time (in seconds) = cu. Ft. per hour. 3. Then cu. Ft. per hour x heating value of gas = input rate (Btuh). On installation without gas meters, check manifold for proper pressure. If fireplace is not installed or warranty card has not been returned to Empire Comfort Systems, Inc., check off type of gas converted to on card. Also, indicated conversion by adding “Conv.” behind type of gas. 41331-1-0220 Empire Comfort Systems Inc. • Belleville, IL Page 3...
  • Page 4 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 4 41331-1-0220...
  • Page 5: Conversion Pour Changement De Gaz Foyer Au Gaz À Ventilation Directe

    31058 POUR CONVERSION AU GAZ PROPANE AVERTISSEMENT Cette trousse de conversion doit être installée par un distributeur Empire Comfort Systems Inc. (ou une agence qualifiée )* conformément aux directives du fabricant ainsi que tous les codes et exigences de l’autorité ayant juridiction. Le défaut de respecter les directives pourrait résulter en de grave blessure ou dégâts matériels.
  • Page 6 [440 mm] de largeur). Poser le nouveau déflecteur du régulateur de tirage (6-5/8 po [168 mm] de largeur, DVP30CC uniquement). Voir Figure 1. 24. Remettre en place le porte-bûches et le fixer au mur arrière en remplaçant les deux vis retirées à l’étape 7. 25. Remettre en place les bûches conformément aux instructions du Manuel de l’utilisateur. Figure 1 26. Placer le cadre vitré sur la chambre de combustion et fixer les deux loquets de porte au bas de la chambre de combustion. Page 2 Empire Comfort Systems Inc. • Belleville, IL 41331-1-0220...
  • Page 7 « Conv. » derrière le gaz. Il faut vérifier que les caractéristiques de la flamme du brûleur principal et la flamme du brûleur de la veilleuse sont correctes, telles que décrites dans les Instructions d’installation et le Manuel de l’utilisateur. VÉRIFICATION DU TAUX D’ENTRÉE DU FOYER CONVERTI Il faut vérifier l’entrée du foyer comme suit : 1. Fermer tous les autres appareils alimentés au gaz. Chronométrer le compteur de gaz et établir le nombre de secondes nécessaires pour consommer un pied cube de gaz. 2. 3600 ÷ temps (en secondes) = pi par heure. 3. Ensuite, pi par heure x pouvoir calorifique du gaz = taux d’entrée (Btu/h). Sur les installations sans compteur de gaz, vérifier la pression du collecteur. Si le foyer n’est pas installé ou que la carte de garantie n’a pas été retournée à Empire Comfort Systems, Inc., cocher le type de gaz converti sur la carte. Indiquer également la conversion en ajoutant « Conv. » derrière le type de gaz. 41331-1-0220 Empire Comfort Systems Inc. • Belleville, IL Page 3...
  • Page 8 Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez communiquer avec votre revendeur. www.empirecomfort.com Page 4 41331-1-0220...