Les langues disponibles

Les langues disponibles

R7284B,P,U,G
Electronic Oil Primary,
EnviraCOM™ Enabled
READ BEFORE INSTALLING
APPLICATION
The R7284B,P,U,G Electronic Oil Primary is a line voltage,
safety rated, interrupted and intermittent ignition oil
primary control for residential oil fired burners used in
boilers, forced air furnaces and water heaters. The
R7284B,P,U,G used with a cad cell flame sensor operates
an oil burner, spark igniter, and optional oil valve. The
control works with a low voltage and optional high
voltage thermostat. The primary controls fuel oil, senses
flame, controls ignition spark (either interrupted or
intermittent) and notifies through the EnviraCOM™ bus a
remote alarm circuit when in lockout.
The R7284 Series of Oil Primary Controls can be used
with both hydronic and forced air systems. When used
with hydronic systems, line voltage switching
Aquastat® Controllers normally provide for the starting
and stopping of the combustion sequences. With forced
air systems, both mechanical and electronic low voltage
thermostats control the starting and stopping of the
combustion process.
Some hydronic and forced air systems require a delayed
valve-on and burner motor-off delay. The R7284
operates an oil valve that prevents the flow of oil when
the burner motor is running prior to combustion
(delayed valve-on) and when the burner motor is
running after combustion (burner motor-off delay).
The R7284 models are intended for use only on oil
burning appliances which do not require prepurge and
post-purge as a safety related function as defined in
UL296. The valve-on delay and burner motor-off delay in
this control are intended only to help establish draft and
reduce oil after-drip related problems.
EnviraCOM™ enabled R7284's can be used with
EnviraLink® remote monitoring systems and hand-held
diagnostics. Use only R7284P and U models for
networking with other EnviraCOM™ enabled devices.
FEATURES
User Interface
There are two user interfaces: basic and advanced. Both
interfaces consist of three buttons: , , and "i."
INSTALLATION INSTRUCTIONS
The advanced interface has a two-line display used to
configure device parameters, retrieve diagnostic
information, and display system status.
The basic interface has a single LED used to display
error codes and system status.
In general, the "i" button cycles through the display
options and acts as an "enter" key (in setup modes).
Thermostat(s)
The oil primaries are compatible with both standard
thermostats and EnviraCOM™ communicating
thermostats.
Limited Recycle
This feature limits the number of recycle trials (for each
call for heat) to a maximum of three trials. If the flame is
lost three times and does not successfully satisfy a call
for heat, the R7284 locks out.
Pump Priming Cycle
To facilitate purging air from the oil lines and filters, the
R7284 can be placed in a purge routine by pressing and
releasing the up arrow button during the Trial For
Ignition.
In the advanced interface "PUMP PRIME" is displayed on
the display along with the time left on the Trial for
Ignition (TFI). Pressing the up arrow button adds a
minute to the TFI time for a maximum of 10 additional
minutes (press the up arrow button 10 times). Pressing
the down arrow button subtracts a minute from the TFI
time.
There is no visual indication for the basic interface
control and the purge timing is limited to five minutes.
Disable Function
Pressing and holding the "i" button will disable all
control functions until 3 seconds after the button is
released.
69-2467EFS-11
Table des Matières
loading

Sommaire des Matières pour resideo EnviraCOM R7284B

  • Page 13: Régulateur Primaire À Mazout Électronique R7284B,P,U,G Compatible Enviracom

    Régulateur primaire à mazout élec- tronique R7284B,P,U,G compatible EnviraCOM™ NOTICE D'INSTALLATION Les modèles R7284 compatibles avec EnviraCOM™ LIRE AVANT L’INSTALLATION peuvent être utilisés avec les systèmes de surveillance à distance EnviraLink® et les appareils de diagnostic de poche. Utiliser uniquement les modèles R7284P et U APPLICATION pour le fonctionnement en réseau avec d'autres dispositifs compatibles EnviraCOM™.
  • Page 14: Fonction De Désactivation

    RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ flèche ascendante ajoute une minute à la durée TFI (appuyer 10 fois pour 10 minutes max. supplémentaires). Verrouillage : 15, 30 ou 45 secondes. Le fait d'appuyer sur le bouton avec touche descendante Remise en marche : 60 secondes (fixe).
  • Page 15: Emplacement

    RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ 1. Le câblage doit être conforme aux codes et aux INSTALLATION règlements locaux. 2. Vérifier que le câblage de la tension secteur est bien connecté. Consulter l'étiquette du régulateur à Lors de l'installation de ce produit... mazout et le schéma de câblage de l'appareil pour 1.
  • Page 16 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ R7284A, G R7284B, P, U VANNE VANNE VANNE BOUTON MOTEUR DE MOTEUR DE MOTEUR DE MOTEUR DE HAUT AFFICHEUR BRÛLEUR BRÛLEUR BRÛLEUR BRÛLEUR BORNES DE MF32180 BOUTON THERMOSTAT Fig. 5. Câblage du R7284 pour vanne à mazout en option. BOUTON i BORNES ENVIRACOM...
  • Page 17 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ CONTRÔLEUR POMPE DE AQUASTAT® CIRCULATION L8148A,C R7284 THERMOSTAT LIMITEUR TH9421C VisionPRO IAQ CAVALIER CONTRÔLEUR AQUASTAT® BORNE ENVIRACOM™ MOTEUR DE L7224/48 MOTEUR DE R7284 BRÛLEUR BRÛLEUR LIMITEUR ALLUMEUR ALLUMEUR VANNE CELLULE DE CELLULE DE BORNE MOTEUR DE MOTEUR DE...
  • Page 18 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ IMPORTANT Le système montré à la Fig. 10 est sensible à la T8635L phase/polarité. S'assurer que toute la C7089B CAPTEUR DE puissance d'entrée est dans la même phase. TEMPÉRATURE EXTÉRIEURE W8635A RELAIS VENTI- LATEUR RELAIS...
  • Page 19: Interface Utilisateur Avancée

    RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ INTERFACE UTILISATEUR AVANCÉE HAUT/BAS ERREUR HISTORIQUE HAUT/BAS (NON SÉLECTIONNÉ) ÉCRAN D’ACCUEIL APPUYER SUR LES 3 BOUTONS (OUI SÉLECTIONNÉ) CELLULE CADMIUM (QUITTER SÉLECTIONNÉ) HISTORIQUE (SUITE SÉLECTIONNÉ) PÉRIOD ALLUMAGE ÉCRANS DE HISTORIQUE CONFIGURATION DE L’INSTALLATEUR COMPTAGE DE CYCLES MF32103A...
  • Page 20: Voir Historique

    RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ Sélectionner entre anglais, français REMARQUE : Le rétablissement des valeurs de et espagnol en utilisant les boutons référence permet d'établir de nouvelles haut et bas et le bouton « i » pour valeurs de référence pour la cellule de cadmium et la durée d'allumage.
  • Page 21: Écrans D'historique Des Erreurs

    RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ Le fait d'appuyer sur « i » au cours de tout écran de durée Description Code DEL d'allumage permet de passer aux écrans de compte de Verrouillage Clignotement de 1/2 seconde sur cycle ci-dessous.
  • Page 22: Dépannage Et Entretien

    RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ DÉPANNAGE ET ENTRETIEN Étapes préliminaires 1. Vérifier les connexions de câblage et l'alimentation. IMPORTANT 2. S'assurer que les régulateurs sont sous tension. En raison des dangers potentiels liés à l'alimen- 3. S'assurer que le limiteur est fermé. tation secteur, seul un technicien d'entretien 4.
  • Page 23 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ Tableau 5. Fonctionnement du R7284. Action externe R7284 Action Puissance appliquée au Vérification de sécurité interne effectuée. Si aucune lumière ou flamme n'est régulateur. détectée et que toutes les conditions internes sont correctes, le régulateur passe en mode de veille.
  • Page 24 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ Tableau 6. Informations sur le dépannage. Condition : Le brûleur ne se lance pas avec l'appel de chaleur Procédure Statut du régulateur Action corrective Revoir l'historique des Consulter le tableau des codes d'erreur dans erreurs si le régulateur est cette section verrouillé...
  • Page 25 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ Tableau 7. Informations sur les alarmes de l'affichage. Numéro d'alarme Alarme de l'affichage EnviraCOM™ Action corrective PAS D'ALLUMAGE • Le brûleur n'était pas allumé et l'étincelle non détectée. Vérifier le bon VÉRIF. ALLUMEUR fonctionnement des électrodes, des contacts à...
  • Page 26 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ Tableau 7. Informations sur les alarmes de l'affichage. (Continued) Numéro d'alarme Alarme de l'affichage EnviraCOM™ Action corrective DÉPASSÉ • La flamme est été perdue plus de fois que le nombre permis. Le RECYCLAGES MAX brûleur s'allume mais ne reste pas allumé.
  • Page 27 RÉGULATEUR PRIMAIRE À MAZOUT ÉLECTRONIQUE R7284B,P,U,G COMPATIBLE ENVIRACOM™ Tableau 8. Codes de clignotement DEL. Code de cligno- Numéro tement d'alarme EnviraCOM™ Action corrective 10,5,20,59,9 Le brûleur n'était pas allumé ni allumé vers la fin de l'essai d'allumage. • Vérifier que le robinet manuel est ouvert. •...
  • Page 28: Avertissement De Sécurité

    This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées. Todos los derechos reservados. Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados.

Ce manuel est également adapté pour:

Enviracom r7284pEnviracom r7284uEnviracom r7284g

Table des Matières