DESCRIPTION
The 1E65-144 thermostat has been designed to control electric heating
systems such as baseboard heaters, radiant fl oors, radiant ceilings
and convectors.
The adapter plate is used to offset the thermostat when an obstruction
prevents the thermostat from being mounted directly to the junction
box.
The thermostat cannot be used with the following:
- a resistive load under 2 A
- a resistive load over 16.7 A
- systems driven by a contactor or a relay (inductive load)
- central heating systems
Parts Supplied:
One (1) thermostat
Two (2) 6-32 pan head screws
SPECIFICATIONS
Supply:
120/240 VAC, 50/60 Hz
Minimum load: 2 A (resistive only)
500 W @ 240 VAC
250 W @ 120 VAC
Maximum load: 16.7 A (resistive only)
4000 W @ 240 VAC
2000 W @ 120 VAC
PRECAUTIONS
* Failure to read and follow all instructions carefully before
installing or operating this control could cause personal injury
and/or property damage.
* All wiring must conform to local and national electrical
codes and ordinances.
INSTALLATION
Installation should be done by a qualifi ed heating and air conditioning
contractor or licensed electrician.
Loosen the screw holding the thermostat cover to the base, open cover
on hinge and remove the cover.
Screw
Available Accessories:
F61-2642 Adapter Plate
WARNING
!
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
1E65-144
Non-programmable Electronic Digital Thermostat
For Line Voltage Applications
INSTALLATION AND OPERATION INSTRUCTIONS
Temperature
Display
Setpoint range:
7°C to 32°C (45°F to 90°F)
Display range:
0°C to 37°C (32°F to 99°F)
Display resolution: 0.1°C (1°F)
Shipping:
–20°C to 50°C (-4°F to 120°F)
Approval:
* To prevent electrical shock, personal injury, and/or equipment
damage, disconnect electric power to system at main fuse or
circuit breaker box prior to installation or service.
Optional: Use the adapter plate accessory if you need to offset the
mounting holes on the junction box. Align and affi x the wall plate to
the electrical junction box using two 6-32 fl at head screws included
with the plate.
Temperature
Adjustment
Buttons
Light
Button
System
Switch
PART NO. 37-6862D
Replaces 37-6862C
0839

Publicité

loading

Sommaire des Matières pour White-Rodgers 1E65-144

  • Page 1 For Line Voltage Applications INSTALLATION AND OPERATION INSTRUCTIONS Operator: Save these instructions for future use! DESCRIPTION The 1E65-144 thermostat has been designed to control electric heating systems such as baseboard heaters, radiant fl oors, radiant ceilings and convectors. Temperature Adjustment...
  • Page 2 INSTALLATION (cont.) Use with copper conductors only. Use wire con- CAUTION NOTE nectors approved for 12 AWG only. Keep the air vents of the thermostat clean and unobstruct- Make the appropriate connections to the thermostat as per diagram ed at all times. Failure to do so can cause harm to your below.
  • Page 3 DIRECTIVES D’INSTALLATION ET D’UTILISATION Utilisateur : Conserver ces directives à titre de référence! DESCRIPTION Le thermostat 1E65-144 est conçu pour commander les systèmes de chauffage électriques, notamment : plinthes chauffantes, planchers Touches de radiants, plafonds radiants et convecteurs. réglage du point La plaque adaptatrice sert à...
  • Page 4 INSTALLATION (suite) Utiliser exclusivement des conducteurs de cuivre. Utili- ATTENTION NOTA ser exclusivement des capuchons de connexion homo- Faire en sorte que les prises d’air du thermostat soient en tout logués pour les conducteurs de calibre 12 AWG. temps propres et libres de toute obstruction, à défaut de quoi Câbler le thermostat en suivant le schéma ci-dessous.