This unit cannot be used in recreational vehicle applications.

How to Install Your CO Alarm

ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or circuit
breaker by removing the fuse or switching the circuit breaker to the OFF position.
Check local codes for specific mounting requirements in your area.
Once you have decided the best place to install the CO alarm(s), follow these
steps:
01. From back of CO alarm, slide mounting plate and lift
from base. See Figure 4.
02. For Model COQ6 only, connect new 9-volt battery to bat-
tery connector inside compartment and slide door closed
snapping it into place.
New 9V battery comes from the factory installed backwards
inside the battery compartment. Replace battery with Eveready
216, 522, 1222 or equivalent from your local retailer.
03. Align mounting plate with junction box mounting holes.
04. Gently pull household wires through center hole of
mounting plate.
05. Secure mounting plate to junction box.
06. With a small wire connector, connect white wire from the CO alarm to
white household wire.
07. Connect black wire from the CO alarm to the black household wire.
08. For interconnecting CO alarms only:
• Use #18 AWG minimum solid or
stranded wire. When interconnecting,
maximum wire length between any
two is 1,500 feet for #18 AWG or
4,000 feet for #14 AWG (20 OHMS
loop resistance.) See Figure 5.
• This CO alarm may be interconnect-
ed with as many as 11 other Firex CO alarms of the
same model. DO NOT connect to any other type or
model CO alarm or other device.
• Connect CO alarms to a single AC branch circuit. If local codes do not permit
connection to a single AC branch circuit, be sure the neutral wire is common to
all circuits used.
09. Plug wiring harness clip onto pins on the
back of the unit.
10. Align tabs on back of base with slots on
side of mounting plate. Slide base down to
lock into position. See Figure 6.
11. Turn power on at the main fuse box or circuit
breaker. The CO alarm will flash the red LED
and emit a short beep during its power-up
cycle. The green power light will stay on as
long as the CO alarm is receiving AC power.
!
WARNING
!
WARNING
!
CAUTION
WHITE
WHITE
WHIT
BLUE
BLUE
BLACK
BLACK
4
FIGURE 4
WHITE
TO NEUTRAL
BLACK
TO 120 VAC (HOT)
FIGURE 5
FIGURE 6