RADIO: 2000W TIMED RELAY MODULE
MTR2000MRP 5454464 2000W modular radio contactor
MTR2000MRPX 5454465
Functions
This module may be used in wireless mode and by one or more
additional local pushbuttons.
Technical Specifications
Mains voltage:
Power on resistive load: Max. 10A 2000W
Power on other loads:
Module consumption:
Radio frequency:
Sound level:
Ambient temperature:
Relative humidity:
Dimensions:
Special features of the MTR2000MRP(X):
Switches may be used instead of pushbuttons with the MTR2000MRP(X) receiver (an E2BP transmitter
must be used).
To establish a connection, switch 5 times rapidly (not 10!), instead of 5 pulses. Simply repeat the connection
procedure with 5 pulses to use a pushbutton instead of the switch again.
WIRING
3 wires
(*) Contact an Urmet retailer or go to www.yokis.com for information on availability
DS1054-023D
All manuals and user guides at all-guides.com
2000W modular radio contactor with
external antenna
230V
±15% - 50Hz
~
please refer to the provided booklet
DS1054-022
< 1VA - < 0.3W
2.4GHz
<60dB a 20 cm
from -20°C to +40°C
0 - 70%
48 x 33 x 22.5 mm
[1.96 x 1.30 x 0.88"]
Connection
button
Test button
State light
4 wires
RAdIO RANGe
Standard Range:
• In the same room (< 100 m²)
• 50 m in open range
POWeR Range (*):
• Inside 100 m² apartments with
perpendicular crossing of main wall or
ceiling
• 250 m in open range
(Note: in both cases the range may be
reduced by the presence of metallic
elements, crossing of walls, or partitions)
RAdIO TRANSMISSION
The transmitter Led will light up only if
the radio transmission was successful.
Adding an intermediate receiver will solve
the problem of an insufficient range.
Refer to the transmitter instruction booklet
for more information.
The module must be installed only by qualified
personnel and into a place the end-user cannot
access, according to the installing national rules.
In order to follow the safety rules, the module must
be connected to a power line that is upstream pro-
tected by a magnetothermic switch 10A C curve.
Except MTV500ER, for all other YOKIS radio
receiver modules you must use a pointed and pro-
perly insulated tool to press the "connect" hole
shortly.
IMPORTANT:
Before starting any configuration, press briefly
23 times to unlock the relay.
The module will lock again automatically after
6 hours.
It can also be locked immediately with 21 short
presses.