4. ASYMMETRICAL LUMINAIRE SPACING
Because every lighting project is different, use the
guide below as a starting point for your lighting design.
To further test the desired effect on your project, use
the photometric files available on B LIGHT's website.
For good uniformity of light on the wall, the spacing (S)
between two luminaires shall be less than twice the
distance (D) from the wall
Example
H
2500 mm / 98"
H
3000 mm / 118"
H
4000 mm / 197"
5. WIRING EXAMPLE ON/OFF: 350 mA -
01 Switch ON/OFF
02 Read section required accessories in each luminaire and choose a 350
mA (constant current) Class 2 power supply UL listed.
03 When connecting the luminaire always observe the correct polarity
(+/-). Failure to do so may destroy the luminaire.
01 Commutateur ON / OFF
02 Lire la section accessoires requis dans chaque luminaire et choisir une
alimentation de classe 2 de 350 mA (courant constant) homologuée UL.
03 Lors de la connexion du luminaire, respectez toujours la polarité
correcte (+/-). Ne pas le faire peut détruire le luminaire.
B LIGHT will not consider valid the warranty conditions and will decline any responsibility for damage when the installation is not carried out according to this installation manual.
B LIGHT ne considérera pas les conditions de garantie valables et déclinera toute responsabilité pour les dommages si l'installation n'est pas effectuée conformément à ce manuel d'installation.
www.b-light.it
ATLAS 60 P
64106 U _ _ _
D
500 mm / 20"
S
500 mm / 20"
MIN
MIN
D
800 mm / 33"
S
1600 mm / 63"
MAX
MAX
D
600 mm / 24"
S
600 mm / 24"
MIN
MIN
D
1000 mm / 39"
S
2000 mm / 79"
MAX
MAX
D
800 mm / 31"
S
800 mm / 31"
MIN
MIN
D
1300 mm / 52"
S
2600 mm / 103"
MAX
MAX
EXEMPLE DE CÂBLAGE ON/OFF: 350 mA
B LIGHT by ADE Elettronica | Via Galvani, 6 - 33083 Villotta di Chions (PN) - Italy | +39 0434 630835
S
D = Minimum H / 5, maximum H / 3
S = Minimum D x 1, maximum D x 2
+ (RED CABLE)
- (BLACK CABLE)
Vf 17,8V DC
NEUTRAL
LINE
GROUND
D
03
02
350 mA
REMOTE
POWER
SUPPLY
01
H
3/4