DESCRIPTION
The 001SIRCEWL is an outdoor curtain-eff ect passive infrared
radio sensor, with adjustable support (up to 190°), with an-
ti-masking and anti-removal tamper features.
The device is fi tted with two IR sensors that work with AND
logic, that is, the alarm is triggered only when both sensors
detect and intrusion.
Precautions
WARNING: the device works on lithium batteries. Handle
with care.
Danger of explosion and fi re. Do not throw out the batteries
into a fi re. Do not heat of damage the batteries.
Respect the marked polarities.
To replace the batteries contact a SKILLED TECHNICIAN.
Dispose of exhausted batteries in compliance with the laws
in eff ect, even when decomissioning the device. If any liquid
comes out, protect your hands with special gloves.
Technical data
Memory
Powered by 2 3 [V] lithium batteries
Draw when standing by [uA]
Draw while in alarm state [mA]
Estimated eff ectiveness [years]*
DUAL-BAND radio transmission frequency
[MHz]
IR Coverage [m]
IR Range [m]
Detectable speed [m/s]
Sensitivity [°C]
Stabilizing time after powering on [s]
11 - 119RF86 ver. 2 11/2014
Operating temperature [°C]
Max. environmental humidity [%]
Sensor's container dimensions [mm]
Power supply and interface module container
dimensions [mm]
Protection rating [IP]
Weight [g]
The sensor's battery life duration is inversely proportional to the
number or detections it is subjected to (regardless of whether
the alarm system is armed or not).
If the sensor is installed in high frequency transit zones, the
battery life may be drastically shortened.
Features
LED
Meaning
Initiation
001SIRCEWL
Alarm
CR123A
Antimasking de -
60
tection
50
Dipswitch
2
868.65/433.92
5x1
2–5
DIP1 (Walk test)
0.3 – 1.5
The LED turns on in case of detection regardless of of
ON
2.0 (a 0.6 m/s)
the DIP4 setting. The DIP2 setting is irrelevant.
120
-20 / +60 °
95 %
155x35x42.5
155x35x42.5
55
215
Indications
Flashes for about 120 seconds.
NOTE. In this phase the LED fl ashes
even if DIP4 is set to OFF
Stays on for two seconds
Flashes three times before repeating
the sequence.
DEFAULT
The LED turns on in case of detection only if it is
enabled, that is, depending on the DIP 4 setting. The
OFF
minimum interval between subsequent detections
depends on the DIP2 setting.
DIP2 (Minimun interval between subsequent detections)
ON Five second interval
120 second interval
OFF
NOTE. The sensor does not trigger an alarm at intervals that are
smaller than the given time.
DIP3 (ALARM and TROUBLE outputs)
ON NO outputs
NC outputs
OFF
For the system to work properly the outputs must be set up in
NC mode (DIP switch 3 OFF)
DIP4 (LED)
ON enabled
disabled
OFF
If the LED turns on even though DIP4 is OFF, check the setting
of DIP1 (walk test)
DIP5 (PIR sensitivity)
ON
Normal sensitivity
Low sensitivity
OFF