High Capacity
Thermostatic Radiator Valves
V110D, E, F
APPLICATION
Honeywell Home thermostatic radiator valves replace
manual valves on radiators and convectors, to provide
automatic temperature control of each unit, space or zone.
They are non-electric and require no outside source of
power. V110 series valve bodies are installed with T104
thermostatic controls. V110 series valve bodies will control
two pipe steam or hot water systems. For control of 1-pipe
steam systems, use V2042 valves.
The thermostatic radiator valves consists of 2 parts: (a)
V110 valve body, with replaceable cartridge and (b) a
thermostatic control T104A, T104F, T104B, T104C, or
T104V. This presents the advantage of being able to
mount the valve body and check the system before the
subsequent installation of the activating head.
NOTE: Before installation, make sure that the right type
of valve and control is selected. Should unex-
pected circumstances make it necessary to
change the type of control head, this can be done
easily because all different types are interchange-
able.
SPECIFICATIONS
Max. Temperature: 248°F (120°C)
Max. Ambient Temperature: 125°F (52°C)
Max. Pressure
Water 150 psi (1033 kPa)
Steam 15 psi (103 kPa)
Max. Differential
17 psi (117 kPa)
40' water column
INSTALLATION INSTRUCTIONS
V110D (Straight Body)
1
C MAX
A
A
C MAX
1
PIPE SIZE
IN. (MM)
IN. (MM)
1/2 INCH
3-3/4 (95)
4-3/4 (121)
3/4 INCH
4-1/8 (105)
4-3/4 (121)
1 INCH
4-15/16 (125)
4-3/4 (121)
1-1/4 INCH
5-7/8 (149)
5 (127)
1 C MAX DIMENSION IS WITH T104 CONTROL INSTALLED.
V110E (Angle Body)
1
C MAX
B
A
A
B
PIPE SIZE
IN. (MM)
IN. (MM)
1/2 INCH
2-9/16 (65)
1 (25)
3/4 INCH
2-5/8 (67)
1-1/8 (29)
1 INCH
3 (76)
1-5/16 (33)
1-1/4 INCH
3-5/8 (90)
1-11/16 (43)
1
C MAX DIMENSION IS WITH T104 CONTROL INSTALLED.
V110F (Horizontal Angle Body)
1
C MAX
A
A
B
PIPE SIZE
IN. (MM)
IN. (MM)
1/2 INCH
2-1/4 (57)
1 (25)
3/4 INCH
2-9/16 (65)
1-1/8 (29)
1 INCH
2-15/16 (74)
1-3/16 (30)
1-1/4 INCH
3-1/2 (89)
2-3/16 (56)
1 C MAX DIMENSION IS WITH T104 CONTROL INSTALLED.
M18959A
C MAX
1
IN. (MM)
4-3/4 (121)
4-3/4 (121)
4-3/4 (121)
5 (127)
M18960A
B
C MAX
1
IN. (MM)
5-1/8 (130)
5-1/4 (133)
5-1/4 (133)
5-1/4 (133)
M18961A
62-2014EF-02

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell Home V110D

  • Page 1 V110D, E, F INSTALLATION INSTRUCTIONS APPLICATION V110D (Straight Body) Honeywell Home thermostatic radiator valves replace manual valves on radiators and convectors, to provide C MAX automatic temperature control of each unit, space or zone. They are non-electric and require no outside source of power.
  • Page 2 HIGH CAPACITY THERMOSTATIC RADIATOR VALVES V110D, E, F INSTALLATION NOTE: For steam application, a Y-strainer should be installed to protect the valve from mal- function and valve should be installed 1. Flush out the system to prevent scale or debris from upside down or in a horizontal position, if fouling the valve seat.
  • Page 3: Typical Installations

    HIGH CAPACITY THERMOSTATIC RADIATOR VALVES V110D, E, F MAINTENANCE The V110 valve cartridge is packed with 2 O-rings (Fig. 1), independent of each other, and will remain tight for many years. To replace the complete insert, a Service Key MT110D119 is used, or, for replacement under pressure, the Cartridge Changer MT110C111 is available for change of complete insert without draining the system.
  • Page 4 The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.
  • Page 5: Vannes De Radiateur Thermostatique Haute Capacité

    Vannes de radiateur thermostatique haute capacité V110D, E, F NOTICE D'INSTALLATION APPLICATION V110D (corps droit) Les vannes de radiateur thermostatique de Honeywell Home remplacent les vannes manuelles des radiateurs et C MAX des convecteurs pour fournir une régulation de température automatique de chaque unité, espace ou zone.
  • Page 6 VANNES DE RADIATEUR THERMOSTATIQUE HAUTE CAPACITÉ V110D, E, F INSTALLATION REMARQUE : Pour les applications à vapeur, un tamis en Y doit être installé pour protéger la vanne d'un dysfonctionne- 11. Rincer le système pour éviter que les écailles ou les ment et la vanne doit être installée en...
  • Page 7: Entretien

    VANNES DE RADIATEUR THERMOSTATIQUE HAUTE CAPACITÉ V110D, E, F ENTRETIEN La cartouche de vanne V110 est emballée avec deux joints toriques (Fig. 1) indépendant l'un de l'autre, et reste serrée pendant plusieurs années. Pour remplacer l'insert complet, une clé de service MT110D119 est utilisée, ou pour le remplacement sous pression, l'outil de remplacement de cartouche MT110C111 est disponible pour remplacer l'insert complet sans avoir à...
  • Page 8 The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.

Ce manuel est également adapté pour:

V110eV110f

Table des Matières