PRECAUTIONS
• Before use, please check that the machine has been assembled completely and
fixed motor components have been mounted and fastened; before this, do not
connect the power supply.
• Before turning on the power, check whether the used voltage is the same as the
voltage indicated on the machine.
• When the appliance works, do not insert your fingers and sharp objects into the
guard or the machine body.
• Children shall use this electric appliance under adult supervision to prevent
accidents. When using an electric mosquito repellant, please ensure that it is out
of reach by children, and if it is accidentally swallowed, seek medical attention
immediately.
• Prior to use, check the power cord and plug for any damage, and if the power cord
is damaged, in order to avoid danger, be sure to have it replaced by the manufac-
turer, maintenance department or professionals with the similar qualification.
• If the appliance is left unattended or is no longer in use, turn off the power and
unplug the power cord to avoid failure problems and accidents.
• When the humidifier is used, the water tank shall use clean water below 40°, and
it is recommended to use demineralized water, pure water or distilled water
containing less impurities.
• Do not place this appliance on sloping ground to avoid tipping over, and do not
move the water tank when the humidifier is working; if the humidifier or host
accidentally tips over when it contains water, please unplug the power cord and
remove the water tank in the machine body, and reuse it after there is no hidden
security risk in the machine and especially no water accumulates in the machine
body.
• When using a humidifier, you can not add sanitizers, vinegar, perfume or essential
oils.
• When using a humidifier, never have the mist to face the furniture, appliances or
walls to avoid damage due to excessive damp.
• Water is inside the water tank or sink shall not be placed for a too long time, as this
may easily breed bacteria; change the water every 2 days, and clean the sink
once every 2-3 weeks.
HUMIDIFIER CLEANING METHOD
• Before cleaning the humidifier, turn off the power, remove the spring clamp and
drain plug, and clear the machine of remaining water.
• After removal of the scale and use for some time, scale is prone to accumulation
inside the water tank, sink, and transducer; if scale occurs in the sink or on the
oscillating blade, a small amount of detergent is put into the water in the sink, and
cleaned with clear water after soaking for about 30 minutes.
• Mount the drain plug and spring clamp.
• Accept it carefully after continuous use or drying the machine in shade.