5.3 Avoiding interference
The device generated a modulated electrical field with a frequency of 13.56 kHz.
To avoid interference of the data communication no other devices generating
interference emission in this frequency band must be operated in the vicinity. Such
devices are for example frequency converters and switched-mode power supplies.
5.4 Mechanical design
On delivery the sensing face is facing the front.
1: Antenna head (can be aligned)
2: Fixing element
5.5 Alignment of the sensing face
1. Loosen the screw.
3. Attach the fixing element to the antenna
head.
6
All manuals and user guides at all-guides.com
Factory setting
2. Remove the antenna head from the fixing
4. Tighten the screw.
180°
90°
element and turn it.