ECL-75, ECL-102
7
Connection
Caution
Make sure that you run the on/off cable away from live power cables.
Warning
To prevent short circuits, always disconnect the negative terminal of the
vehicle battery before working on the vehicle electrical system.
If the vehicle has an additional battery, its negative terminal must also
be disconnected.
Warning
The cable cross section for the connection between the starter battery, power
relay and consumer battery must not be less than 16 mm² for the ECL-75 and
25 mm² for the ECL-102. Also check that the cable between the negative
terminal of the consumer battery and vehicle chassis is at least 16 mm² and
25 mm² respectively – you might need to replace the cable provided with a
thicker one. The minimum cable cross sections are listed in the following table.
The table shows the combinations possible of roof air conditioners, charging current
distributors and inverters and the necessary cable cross sections of the access leads:
Charging current
Roof air
distributor
conditioner
(item no.)
Dometic CA1000
ECL-75
Dometic CA1000
ECL-102
Dometic CA2500
ECL-102
Dometic CA2500
ECL-102
Dometic B1600
ECL-102
Dometic B1600
ECL-102
Dometic B1600 Plus ECL-102
Dometic B1600 Plus ECL-102
Dometic B2200
ECL-102
Dometic B2200
ECL-102
Dometic HB2500
ECL-102
Mount the ECL-75 / ECL-102 charging current distributor and the corresponding
relay in such a way that they remain fixed, dry and well-ventilated, ideally in direct
proximity to the inverter.
All manuals and user guides at all-guides.com
Inverter
(item no.)
PerfectPower PP1000
(8100-12VS)
SinePower SP1500
(item no. MSK1500-012)
ECW-012VS
SinePower SP1500
(item no. MSK1500-012)
ECW-012VS
SinePower SP1500
(item no. MSK1500-012)
ECW-012VS
SinePower SP1500
(MSK1500-012)
ECW-012VS
SinePower SP1500
(item no. MSK1500-012)
SinePower SP1500
(item no. MSK1500-012)
Connection
Cable cross
section
16 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
25 mm
minimum
2
39

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Waeco ecl-102

Table des Matières