Installation instructions for SELVE burglar-proof fixation
SecuBlock / SecuBlock XL
Dear customer,
By purchasing this burglar-proof fixation from SELVE, you have chosen to purchase
a quality product. Thank you for buying this product and for putting your trust in our company.
Before you start working, we ask you kindly to read these instructions and observe
the safety instructions in particular.
Intended use:
The burglar-proof fixation is only to be used to secure roller shutters.
Any other form of use can only be conducted after consulting with Selve.
The information given in these instructions are based on our current knowledge and experiences.
Due to the abundance of influences when it comes to processing and application, these instructions do not exempt the processor
from conducting their own tests and trials. Our information cannot provide a legally binding guarantee concerning certain pro-
perties or suitability for any specific purpose. It is the responsibility of the recipient of our products to adhere to any laws and re-
gulations.
Installation instructions:
For the models with a fixing bar:
The burglar-proof fixation can be connected without screws if the octagonal shaft has
rectangular cuttings (5.5mm x 8mm). To do this the bar needs to be set to cuttings S and
the slot R needs to be turned by using a coin or the like by 30° in direction of arrow as
far as it will go.
Attention – when turning the slot R the clip snaps hearable into place.
The burglar-proof fixation can be demounted by turning back the slot against the directi-
on of arrow and can be new positioned on another collar.
Technical data:
Shaft connector
Application box depth (B)
SecuBlock: without connecting part
part
115 mm – 150 mm
SecuBlock: 1-
SecuBlock: 2-
part
155 mm – 180 mm
SecuBlock: 3-
part
185 mm – 210 mm
part
215 mm – 240 mm
SecuBlock: 4-
part
125 mm – 160 mm
SecuBlock XL: 1-
part
160 mm – 200 mm
SecuBlock XL: 2-
SecuBlock XL: 3-
part
200 mm – 250 mm
1
The data is among other things depending on the type of tube. ·
When assembling the burglar-proof fixation, the first one on the left and right should be
positioned outwards as far as possible (X).
It is recommended to use one burglar-proof fixation per approx. 600 mm
length of octagonal shaft (Y) or per 4 Nm (XL: 6 Nm) motor performance.
Assembly with screws:
When installing with screws please make sure that the outside of the motor
will not come into contact with the screws.
Recommended screws for steel shaft 60 / steel shaft 70: 3.5 x 6.5 DIN 7981 F H
Please note: The motor can be damaged if other screws are used!
The last slat of the roller shutter must not protrude from the guide rail by more than 1/2
of the profile height (A)!
The "anti-lift effect" only works if the individual parts support one another and the
upper roller shutter profile is pressed downwards!
1
80 mm – 110 mm
2
When used with article 289122 · Subject to technical changes!
SELVE GmbH & Co. KG · Werdohler Landstraße 286 · D-58513 Lüdenscheid
Telefon +49 (23 51) 9 25 -0 · Telefax +49 (23 51) 9 25-111 · www.selve.de · info@selve.de
Number per hanging
One burglar-proof fixation per
60 cm length of shaft or per
4 Nm motor performance
One burglar-proof fixation per
60 cm length of shaft or per
6 Nm motor performance
Hanging weight
min.- / max.-profile
max. 8 kg per burglarproof
from SW 40 x 0,6 mm
fixation
up to SW 60 x 1,0 mm
min.- / max.-profile
max. 12 kg per burglar-
from SW 60 x 0,9 mm
proof fixation
up to SW 70 x 1,5 mm
GB
Application area
2
2