III. INSTALLATION INSTRUCTIONS - PRECAUTIONS
The installer must be a qualified technician. Disconnect electrical
power before begining installation. Do not install the humidistat
on the warm air duct. Conduct a thorough checkout before leaving
the installation.
WALL MOUNT INSTRUCTIONS - Humidistat/Dehumidistat
versions
1. Choose a location for the MXH3 about five feet above the floor
on an inside wall with average room temperature and relative
humidity conditions.
2. Drill a small hole in the wall and run low voltage wiring to the
location chosen. Pull about 6" of wire through the hole.
Use the entire mounting gasket (both inside and outside
portions) to seal the wall opening or use foam tape to prevent
drafts from affecting the humidistat operation. (see fig 3.)
3. Remove the knob on the humidistat. Squeeze the top and
bottom of the base to release the face of the humidistat.
4. Mount the base horizontally over the wires. Attach directly to
the wall, using the two screws provided in the slotted holes.
5. Connect the wires to the screw terminals on the control assembly
as shown in wiring DIAGRAMS 1-5 Replace face and Knob.
DUCT MOUNTING ON THE RETURN AIR - WALL BASE
Humidistat/Dehumidistat versions (optional)
Do not install the humidistat on the warm air duct or within 48"
of UV light.
1. Locate the humidistat at least 24" upstream of the humidifier or
bypass on the return air duct. Avoid areas of direct radiation like
secondary heat exchanger in the fan compartment.
FIG. 1
2. Cut a square in the duct 2-1/4" wide and 1-3/4" tall. Remove the
WALL MOUNT VERSION
inner portion of the mounting gasket and discard. Use the outer
portion to seal between the plastic base and the duct. Line up the
base with the cut out and accurately mark the holes thru the plastic
duct mount
plate. (see fig 3.)
3. Revove the humidistat and drill four 3/32" mounting holes.
4. Place the outer portion of the mounting gaskets on the plastic base
and mount the base with four screws. Low voltage wire may enter
the humidistat under the gasket.
5. Connect wires to screw terminals on the control assembly as
shown in wiring DIAGRAMS 1-5. Replace the face and knob.
DUCT MOUNTING ON THE RETURN AIR - DUCT BASE
Humidistat/Dehumidistat versions (recommended)
Do not install the humidistat on the warm air duct or within 48"
of UV light.
1. Locate the humidistat at least 24" upstream of the humidifier
or bypass on the return air duct. Avoid areas of direct radiation
like secondary heat exchanger in the fan compartment.
2. Remove face by inserting screwdriver into the pry slot and
twisting (see fig. 2)
3. Use the plastic duct mount plate as a template. Accurately mark
and drill the (4) 3/32" mounting holes and cut away the 4-1/4" x 2-1/2"
section of the duct mount plate.
4. Place duct mount base gasket on the humidistat base and mount
the base with four screws. Low voltage wire may enter the humidistat
under the gasket (see fig. 2)
5. Connect wires to screw terminals on the control assembly as shown in
wiring DIAGRAMS 1-5. Replace face and knob.
MHX3 CALIBRATION INSTRUCTIONS
(Accurate humidity gauge required)
1. Use an accurate humidity gauge to determine the current relative
humidity in the room where the humidstat is located. This relative
humidity will be used in step 5.
2. Remove the face plate from the housing.
3. Turn the knob on the MHX3 faceplate to the "on" position
4. Very slowly, turn the knob clockwise until you hear a "click" from
the humidistat control and leave the knob in this position.
5. Turn the ring (not the knob) so that the knob is pointed directly
at the current relative humidity number determined in STEP 1.
6. The humidistat in now calibrated to match you humidity gauge.
1. If mounted on wall, verify wire clearance hole in wall is sufficiently
Humidifier turns
insulated to preven drafts from affecting the humidistat.
on and off
2. If mounted on return air duct, verify humidistat is at least 24"
repeatedly
upstream of humidifiers air discharge.
1. When the humidity in the home is less than the knob setting on
Humidifier
the humidistat the stat will operate the humidfier until the humidity
operates
is higher. Reduce knob setting.
continuously
2. Verify function of solenoid valve.
1. Set the thermostat to operate both furnace burner and blower.
No humidifier
Operation may be necessary for system power.
operation in "ON"
2. Verify terminals 2 and 3 are used on the humidistat. These are the
mode
contacts for humidification.
3. Check voltage at at terminals 2 and 3. There should be no voltage
for an Elite Steam or 1137/1000 power humidifier. Voltage should
be 20-30 VAC from most others.
4. Verify humidifier operation by bypassing the humidistat.
Ideal humidity is
1. Technical fault with humidifier. Check water supply, electrical
connnections and condition of the evaporator pad. Verify metering
not achieved
orifice at the solenoid valve is not obstructed.
2. Humidifier run time is too short. Switch water supply to hot water if
appropriate (use copper tubing).
3. Excess air infiltration. Seal sources of air loss.
4. Humidifier is undersized. Switch water supply to hot water if
appropriate (use copper tubing). Add additional unit(s) or
replace existing unit with a larger unit.
NC
C
USE TERMINALS C AND NO FOR HUMDISTAT
NO
HMX3
Humidistat
DIAGRAM 2 WIRING HIGH LIMIT HUMIDISTAT WITH ELITE STEAM HUMIDIFIER
N2
GND
N1
AB
AB
GND
IN
NO
C
NC
C
NO
GND
24V
USE TERMINALS C AND NO FOR HUMDISTAT
DIAGRAM 3
WIRING 120V. 1137/1000 POWER HUMIDIFIER
HUMIDIFIER CONTROL LEADS
HUMIDIFIER
HUMIDIFIER 24V AUX POWER
(YELLOW WIRES)
POWER CORD
(RED WIRES)
HUMIDISTAT
NC
C
NO
USE TERMINALS C AND NO
G
FOR HUMDISTAT
L1
N
110V SWITCHED WITH FURNACE HEATING CYCLE
WIRING 120V. 1137/1000 POWER HUMIDIFIER
DIAGRAM 4
HUMIDIFIER CONTROL LEADS
HUMIDIFIER
(YELLOW WIRES)
POWER CORD
HUMIDISTAT
NC
C
NO
FIELD SUPPLIED RELAY
24V COIL, N.O. 5A MIN.
G
USE TERMINALS C AND NO FOR HUMDISTAT
N
L1
L1
N
110V SWITCHED WITH
110V CONSTANT VOLTAGE
FURNACE HEATING CYCLE
DIAGRAM 5
1300 DEHUMIDIFIER
USE TERMINALS C AND NC FOR DEHUMDISTAT
HUMIDISTAT
NC
C
NO
NC
C
NO
HUMIDISTAT
(NOT USED, ATTACH WIRE
NUTS TO EACH LEAD)
DO NOT TOUCH TOGETHER!
HUMIDIFIER 24V AUX POWER
(RED WIRES)
(NOT USED, ATTACH WIRE
NUTS TO EACH LEAD)
DO NOT TOUCH TOGETHER!
GENERALAIRE 1300
DEHUMIDIFIER
DH
D
Y
W
C
G1
G2
S1
S2
FORM NO MHX3-06 REV C

Publicité

loading

Sommaire des Matières pour GeneralAire MHX3

  • Page 1 2. Remove the face plate from the housing. HUMIDIFIER CONTROL LEADS HUMIDIFIER HUMIDIFIER 24V AUX POWER 3. Turn the knob on the MHX3 faceplate to the “on” position (YELLOW WIRES) POWER CORD (RED WIRES) 4. Very slowly, turn the knob clockwise until you hear a “click” from HUMIDISTAT the humidistat control and leave the knob in this position.
  • Page 2 WARRANTY REGISTRATION You may register online at www.GeneralAire.com or mail form below Product Information: Serial Number: _____________________________________________________________ Model: ____________________________________________________________________ Install Date: Month _______________ Day ______________ Year _____________ Fresh Indoor Air Quality Owner Information: Name: _____________________________________________________________________ Address: ___________________________________________________________________ Mail Form To:...
  • Page 3 TERRE 2. Retirer la plaque frontale du boîtier. ENTRÉE (IN) 3. Tourner le bouton du boîtier MHX3 jusqu'à la position «ON». 4. Très lentement, tourner le bouton vers la droite jusqu'à ce que HUMIDISTAT vous entendiez un "clic" du régulateur d’humidité (humidistat) et laisser le bouton dans cette position.
  • Page 4 ENREGISTREMENT DE LA GARANTIE Le produit peut être enregistré en ligne au www.GeneralAire.com ou par la poste en envoyant le formulaire ci-dessous Renseignements sur le produit : Numéro de série : ____________________________________________________________ Modèle : ___________________________________________________________________ Date d’installation : Mois _______________ Jour ______________ Année ____________ Fresh Indoor Air Quality Renseignements sur le propriétaire :...