ITC POWER TOOLS FSCN2-1 Guide D'utilisation page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING PROCEDURES
CLEARING A JAMMED FASTENER
1. Disconnect the tool from the air supply.
2. Open the magazine cover. Remove any remaining fasteners from the tool.
3. Use a slender, soft steel rod to push the drive blade to its uppermost position.
Remove the jammed fastener with needle nose pliers.
4. Follow instructions in LOADING THE FASTENERS to reload fasteners.
MAINTENANCE
CAUTION:
 Disconnect tool from air supply before cleaning and inspection.
 Correct all problems before putting the tool back in service.
1. Wipe tool clean and inspect for wear or damage. Use non-flamable cleaning
solutions to wipe exterior of tool only if necessary. Do Not Soak tool with
cleaning solutions. Such solutions can damage internal parts.
2. Inspect trigger and safety mechanism to assure system is complete and func-
tional: no loose or missing parts, no binding or sticking parts.
3. Keep all screws tight. Loose screws can cause personal injury or damage the
tool.
4. If the tool is used without an in-line oiler, place 2 drops of air tool oil into the air
inlet of the tool at the beginning of each workday and after about 1 hour of con-
tinuous use. Frequent but not excessive lubrication is required for best perfor-
mance. Oil added through the airline connection will lubricate all internal parts.
Use only air tool oil. Do not use oil with detergents or other additives. These can
cause damage through accelerated wear to the seals in the tool.
5. Use a small amount of oil on all exterior moving parts and pivots.
6. Dirt and water in the air supply are major causes of pneumatic tool wear. See
the section on SETUP: AIR SYSTEM for more information.
7. Keep tools clean for better and safer performance. Use non-flammable clean-
ing solutions sparingly and only if necessary. Do not soak parts in the solutions.
Such solutions may damage O-rings and other parts.
TROUBLESHOOTING
WARNING: Stop using the tool immediately if any of the following problems occur.
Serious personal injury may result. Any repairs or replacements must be
done by qualified personnel or by an authorized service centre only.
CAUTION: Disconnect the tool from air supply before performing any service
procedure.
When inserting new or re-installing O-rings, make sure they are clean and lubricated
with an O-ring lubricant.
6