Range Hood
INSTALLATION MANUAL
SAFETY INSTRUCTIONS
Before installation and operation, read these instructions carefully
and use this product only in the manner described by the
manufacturer in the operation manual.
The instruction shown below are used to alert you to potential
personal injury and property damage hazards.
There are three hazard classifications based on potentially
dangerous situations.
Obey all safety instructions that show these symbols to avoid
possible injury, death and property damage.
WARNING:
WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION:
CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
CAUTION:
CAUTION used without the safety
alert symbol indicates a potentially
hazardous situation which, if not
avoided, may result in property
damage.
NOTE: The safety instructions are explained with the following
pictographic symbols.
means prohibition. It indicates actions, if any, that
mustn't be done.
means forcible execution. It indicates actions, if
any, that must be done.
WARNING
1. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning the unit, switch power
off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
2. To reduce the risk of fire or electric shock, do not
use this product with any solid-state speed control
device.
3. Do not attempt to control Remote Blower using
the internal switch provided on the front panel of
the BUF-06E.
THIS SWITCH IS TO BE USED FOR THE
CONTROL OF THE LIGHTS ONLY! A SEPARATE
S W I T C H , W I T H P R O P E R LY R AT E D
A M P E R A G E M U S T B E I N S TA L L E D TO
CONTROL THE REMOTE BLOWER MOTOR.
Contact the Remote Blower manufacturer or a
Certified Electrician for their recommendations.
1. Preparation
WARNING:
• If the range hood is not installed properly, it could become detached
and fall.
• Ensure that the metal duct does not touch other metal housing
materials, otherwise fire or electric shock could result.
1
According to the conditions where the range hood is installed, de-
termine whether it will discharge vertically or horizontally (10" Round
duct). For vertical or horizontal discharge, run duct work between
the hood location and the exterior blower used with the range hood.
For the best result in either directions, use a minimum number of
transitions and elbows.
* As for installing the exterior blower, please refer to its installation
manual.
EXTERIOR
BLOWER
10" ROUND DUCT
(For vertical
discharge)
SOFFIT
SOFFIT
10" ROUND DUCT
RANGE HOOD
RANGE HOOD
(For horizontal
discharge)
2
The range hood unit must be mounted to a liner which has the
following dimensions. Install the liner securely after checking that
the opening size of the liner is the same as the figure below.
4-Ø1/4" (4-Ø6.5)
25-3/16" (640)
26" (660)
CAUTION:
The liner should be installed tightly. If the liner installation is not correct,
the range hood unit may become detached and fall.
4. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction.
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer's
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and The American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d) Ducted fan must always be vented to outdoors.
5. TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
6. This unit must be grounded.
7. Install this range hood to a liner. Check that the
hood is correctly installed, since incorrect
installation could result in the range hood
becoming detached and falling off.
8. Connect only to an AC120 Volt power source or
the range hood could result in fire, electric shock,
and damage.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
2. To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls, ceilings or into attics,
crawl spaces or garages.
3. Read specification label on this product for further
information and requirements.
4. Use only for the purpose of kitchen ventilation.
5. Do not install this range hood in the bathroom or
in other wet rooms since electrical shock and
damage may result.
6. Fasten the filter and other parts securely. Incorrect
attachment may result in personal injury or
property damage.
7. To reduce the risk of fire and electric shock, install
this range hood only with remote blower models
rated maximum current of 12.8 amps.
2. Range Hood Mounting
CAUTION:
• Wear working gloves to avoid injury.
• To prevent air or moisture from entering through the wall opening, be
sure to install wall insulation to seal around duct work completely.
1
Remove 5 screws fixing the front
cover and detach the front cover.
2
Hold up the range hood and align the 4 screw holes of the liner and
range hood, then fix securely using the supplied screws (M5×30)
and nuts.
EXTERIOR
Note: Fasten all the screws and nuts evenly.
BLOWER
Securing plate
[Securing plate turns
while passing through
Unit: inch (mm)
the opening of Liner]
Four screws (M5×30)
3
Check that the top of the exhaust
port is inserted into the bottom of
10" round duct, then make the duct
joint secure and air tight using non-
flammable tape such as duct tape,
etc. (not supplied)
MODEL: BUF-06E
NAMES OF PARTS
Front Cover
ON
OFF
Lamp Switch
Filter
SIZE & DIMENSIONS
¯7/8" (¯22.6)
9-13/16" (250)
26" (660)
25-1/16" (636)
23-3/8" (594.2)
27" (686)
17-11/16" (450)
12-3/8" (314)
12-3/8" (314)
INSTALLATION
3. Connecting Power Supply Wires
WARNING:
• Electrical wiring should be done by a qualified person(s) in
accordance with all applicable codes and standards, including
fire-rated construction. An unqualified person doing the work could
result in fire, electric shock or injury.
• This range hood uses 120V AC. Do not connect to other voltage
since fire, electric shock or damage could result.
1
Remove the nut from the conduit connector
at the end of power wiring.
WARNING:
Be sure to switch power OFF at service
panel before wiring.
2
Remove two screws fixing the wire cover and detach it.
3
Connect the conduit through the connecting hole of the body using
the nut previously removed.
Screw-washer
[Right & left,each
4
Connect the electrical wires as follows:
two (2) places]
• Black to Black
• White to White
Connect wires tightly and securely using wire connectors
(not supplied).
Liner
5
Replace the wire cover with the screws removed previously. Make
sure that all wires are connected properly and enclosed inside
of the wiring compartment.
CIRCUIT DIAGRAM
Enclosure
Switch (Lamp)
120V 60Hz
Green
White
Black
Black
White
Connector
Connector
ACCESSORIES
Unit: inch (mm)
4-¯1/4" (¯6)
Screw M5×30
Four (4) pieces
15-13/16" (401.2)
9/16"
(14)
RANGE HOOD LOCATION
6-3/4" (172)
14-1/8" (358.4)
¯9-15/16"(¯253)
1
The range hood must be in-
stalled just above the cooktop.
2
The minimum distance from the
cooking surface to the bottom
of the range hood must be 24".
3
The total weight of the BUF-06E
range hood unit is 11 lbs. (5 kg)
4
Power requirements are:
AC120 V, 60 Hz, 1.0 Amp
CAUTION:
• Check that the hood is correctly installed, since incorrect
installation could result in the detachment of the range hood
and the unit could fall.
• To protect hands from injury, wear working gloves when
installing the range hood.
4. Final Assembly and Check
Two 50 W halogen light bulbs (not supplied) can be mounted in this
range hood.
Prior to final assembly, install light bulbs (PAR20 bulb, in the base
diameter 26 mm: medium base), rated 120 V - 50 W or below.
1
Assembly
Attach the front cover, and secure it with 5 screws.
Then attach the filters.
Conduit
(Not supplied)
Nut
(Not supplied)
Turn the lamps clockwise to fix them.
2
Check
(1) Turn on the electrical circuit to the range hood.
(2) Make sure that the switch and light operate correctly.
Refer to page 5 of the Operation Manual.
(3) Make sure that the range hood functions rightly and it has no
abnormal noises and/or vibration.
• Green to Green
* As for operating the exterior blower used with this hood, please
refer to its operation manual.
5. Explanation to the End User
(1) Referring to the Operation Manual, explain the operation of this
range hood to end users.
(2) The Installation Manual and Operation Manual should be given to
the end user.
1U03 1181
Connector
Lamp:50W
Black
Black
White
White
Terminal
Connector
Black
Lamp:50W
Black
Black
White
White
White
Terminal
Nut with plate
Four (4) pieces
Liner
24" (Minimum)
Cook top
Push to turn ON