Agilent Technologies F Série Instructions D'installation page 17

Table des Matières

Publicité

DANGER : DANGER DE DÉCHARGE ÉLECTRIQUE DÉBRANCHEZ L'ALIMENTATION DE L'APPAREIL AVANT L'ENTRETIEN
DISPOSITION DES COMPOSANTS DE L'APPAREIL
MODULE DE VENTILATEUR
OFM
EXTÉRIEUR
PARTIE DU BOÎTIER DE COMMANDE
MODULE DE
MODULE DE
COMPRESSEUR
VENTILATEUR
CONNEXIONS
INTÉRIEUR
REGROUPÉES POUR
CHAUFFAGE
IFM
TRAN
LPS
ÉLECTR. AUXILIAIRE
LE CAS ÉCHÉANT
IFB
HPS
COND
VOIR LE SCHÉMA DU
H
CHAUFFAGE POUR
COMP
LE CÂBLAGE
R
S
CCH
BOÎTIER
Thermomètre sec
D'ÉPISSURE
DE 24 V
DR
PRISE DE
L'ÉCONOMISEUR
ÉCONOMIQUE
CONNEXIONS
MONTRÉS PRÈS
ROSE
BLEU
SAM
DU CONTACTEUR
ROSE
BLEU
GRIS
JAUNE
ROUGE
BRUN
NOIR
P1
ROUGE
BRUN
T-STAT
JAUNE
Y2
O
VOIR
R
REMARQUE 11
VOIR
REMARQUE
R
R1
C
12
Y
NOIR
G
JAUNE
JAUNE
DH
NOIR
W
VOIR REMARQUE 12
V
REMARQUES :
1.
SI VOUS DEVEZ REMPLACER UNE PARTIE DU CÂBLAGE D'ORIGINE, VOUS DEVEZ LE REMPLACER PAR UN CÂBLAGE DE MÊME TYPE OU
L'ÉQUIVALENT.
2.
VOIR LA DOCUMENTATION DE COMMANDE DES THERMOSTATS.
3.
UTILISEZ DES CONDUCTEURS EN CUIVRE DE 75 C POUR LES RACCORDEMENT SUR PLACE.
4.
CONSULTEZ LES INSTRUCTIONS D'INSTALLATION POUR LA SÉLECTION APPROPRIÉE DU MOTEUR DE VENTILATEUR INTÉRIEUR
5.
IL EST PARFOIS NÉCESSAIRE DE RELOCALISER LES PRISES DE VITESSE POUR LES DISPOSITIFS DE CHAUFFAGE INSTALLÉS SUR
PLACE. CONSULTEZ LES INSTRUCTIONS D'INSTALLATION POUR DÉTERMINER LE CHOIX DES PRISES DE VITESSE APPROPRIÉ.
6.
NE DÉBRANCHEZ PAS LES PRISES LORSQUE LE DISPOSITIF EST EN CIRCUIT.
7.
CE FUSIBLE DE MARQUE LITTLE FUSE PORTE LE NUMÉRO DE PIÈCE 287003.
8.
LA FONCTION DE DÉSHUMIDIFICATION N'EST PAS DISPONIBLE AVEC UN ÉCONOMISEUR. APPAREIL EXPÉDIÉ DE L'USINE EN MODE
STANDARD.
9.
N.E.C. (NATIONAL ELECTRICAL CODE) CLASSE 2, 24 V.
10. CHAUFFE-CARTER NON UTILISÉ SUR TOUS LES MODÈLES.
11. RETIREZ L'ÉPISSURE JAUNE POUR L'UTILISATION D'UN ÉCONOMISEUR ET D'UN RELAIS D'ÉCONOMISEUR ET EFFECTUEZ LES
BRANCHEMENTS AU RELAIS R1 COMME MONTRÉ.
12. POUR L'UTILISATION D'UN ÉCONOMISEUR ET D'UN RELAIS D'ÉCONOMISEUR, BRANCHEZ LES FILS JAUNE ET NOIR AU RELAIS R COMME
MONTRÉ. UN NÉCESSAIRE DE RELAIS EST REQUIS POUR LES APPAREILS AVEC ÉCONOMISEUR ET À THERMOPOMPE/DEUX
COMBUSTIBLES.
13. POUR L'UTILISATION D'UN ÉCONOMISEUR ET D'UN RELAIS D'ÉCONOMISEUR, BRANCHEZ LES FILS COMME MONTRÉ AUX BOBINES DES
RELAIS R ET R1.
Figure 15 – Schéma de connexion de câblage
51801200405FR
SCHÉMA DE CONNEXION DE CÂBLAGE
SCHÉMA 208/230 3-60
ALIMENTATION
FOURNIE SUR PLACE
TERRE ÉQUIP.
APPAREIL SEULEMENT –
SECTIONNEUR
SECTION MAXI. DE
CONFORME NEC
CONDUCTEUR : 2 AWG
ENTRÉE D'ALIMENTATION
DE 24 V
LPS
HPS
BLEU
BLEU
NOIR
BLEU
Thermomètre sec
OF1
RVS
BRUN
NOIR
OF2
BLEU
P3
DFT
ROSE
R
ROSE
Y
P2
T1
C
C
O
W1
J1
Y
O
R W2
C
SPEEDUP
BLANC
JAUNE
BRUN
ROUGE
MASSE
ORANGE
COM/C
COM
C FAIBLE
PAR LE
SUPPORT
VOIR REMARQUE 7
GRIS
ORANGE
ROUGE
BRUN
P2
P1
JAUNE
VERT
BLEU
BLANC
VIOLET
Specifications are subject to change without notice.
SELON
L'ÉQUIPEMENT
CHS
CCH
NOIR
NOIR
VERT
NOIR
C
L1
NOIR
L3
JAUNE
JAUNE
TERRE ÉQUIP.
NOIR
L2
BLEU
NOIR
JAUNE
NOIR
COM
TRAN
C
24 V
C
C2
C1
DFT
C2
C1
C1
C2
BRUN
VOIR REMARQUE 13
ROUGE
VOIR REMARQUE 8
ÉLEVÉ
FICHE
BRUN
IFB
BLANC
VIOLET
Y
P4
ROSE
GRIS
FAISCEAU
PRINCIPAL
LÉGENDE
ÉPISSURE FOURNIE SUR PLACE
BORNE (MARQUÉE)
BORNE (NON MARQUÉE)
ÉPISSURE
ÉPISSURE (MARQUÉE)
BASSE TENSION USINE
CÂBLAGE DE COMMANDE
FOURNI SUR PLACE
CÂBLAGE ÉLECTRIQUE SUR LE
TERRAIN
CÂBLAGE ACCESSOIRE OU EN
OPTION
HAUTE TENSION USINE
208/230 V, 3 phases, 60 Hz
DR
NOIR
NOIR
NOIR
OFM
COND
JAUNE
C
F
BRUN
JAUNE
COMP
T1
T3
T2
GND
N
JAUNE
GND
VERT/JAUNE
NOIR
L1
VOIR
COM
REMARQUE 6
VERT/JAUNE
BRUN
VOIR REMARQUES 4/5
BRUN
CHAUFFAGE ÉLECTRIQUE AUXILIAIRE (SI UTILISÉ)
FICHE
BRUN
HR1 (5 KW)
HR1
BRUN
BLANC
HR1, 2, 3 ET 4 (20 KW)
BRUN
HR4
VIOLET
BRUN
ROSE
HR2
BRUN
HR1 ET 2 (10 KW)
HR3
GRIS
HR1.2 ET 3 (15 KW)
CHAUFFAGE
AUXILIAIRE
C
CONTACTEUR
CAP
CONDENSATEUR
CCH
CHAUFFE-CARTER
COMP
MOTEUR DE COMPRESSEUR
DB
CARTE DE DÉGIVRAGE
DH
MODE DE DÉSHUMIDIFICATION
DFT
CONTACTEUR DE TEMPÉRATURE DE DÉGIVRAGE
DEHUM
MODE DE DÉSHUMIDIFICATION
DR
RELAIS DE DÉGIVRAGE
ECON
ÉCONOMISEUR
EQUIP
ÉQUIPEMENT
GND
MASSE
HPS
PRESSOSTAT HAUTE PRESSIONHR RELAIS DE CHAUFFAGE
IFB
CARTE DE VENTILATEUR INTÉRIEUR
IFM
MOTEUR DE VENTILATEUR INTÉRIEUR
LPS
PRESSOSTAT BASSE PRESSION
OFM
MOTEUR DE VENTILATEUR EXTÉRIEUR
OFR
RELAIS DE VENTILATEUR EXTÉRIEUR, BEIGE
RVS
ROBINET INVERSEUR
STD
MODE STANDARD
TRAN
TRANSFORMATEUR
T-STAT
THERMOSTAT
IFM
A150520
17

Publicité

Table des Matières
loading

Produits Connexes pour Agilent Technologies F Série

Ce manuel est également adapté pour:

Phd4B sérieWph4