EN
Commissioning
1
Mounting
Mounting via holes for M4-sized screws in the case or via a BT 56 / BT 59 mounting
system (accessory).
A Optical axis
B Optical swivel range:
NOTE
Degree of protection IP 65 is achieved only if the connectors and caps
are screwed into place!
2
Electrical connection – Commissioning with factory settings
 Connection of the BCL 3xxi via the MS 3xx, MK 3xx, ME 3xx, or via the MA 100
with KB 301 - 3000.
 Connect voltage supply and, if necessary, switching input, USB service interface
and host/bus interface.
 Switch on operating voltage, PWR LED must illuminate green.
 Activate scanner via switching input; the laser switches on.
 Hold the following "LEUZE" sample bar code up to the BCL 3xxi at a distance of
approx. 100 ... 200mm.
Upon successful completion of the read operation, the sensor beam switches off
and the read result is shown in the display.
 End the reading gate by removing the switching input signal or with the aid of the
key pad / display.
17
Oscillating mirror version = ± 20°